Fire Behavior
Building Construction
ICS/Communications
Haz-Mat
Equipment
NFPA Standards
100

Prior to entering a fire area with a charged hoseline, the nozzle operator should first?

Bleed the air from the line.

100

The five types of building construction are?

Fire Resistive - Type 1

Non-combustible - Type 2

Ordinary - Type 3

Heavy Timber - Type 4

Wood Frame - Type 5

100

The term for a roll call taken by a supervisor at an emergency incident is a?

Personnel Accountability Report.

100

Vapors and gases with a vapor densities less then 1 will tend to:

Rise up in the air

100

What does the "irons" consist of?

Halligan and axe

100

What is the standard for firefighter professional qualifications?

NFPA 1001

200

When forcing entry, where should the halligan tool be placed?

Space between the door jam and door near the lock.

200

Opening a wall is know as:

Breaching

200

The most commonly accepted order of fire ground priorities is referred to through this acronym?

LIP

Life Safety - Incident Stabilization - Property Conservation

200

Atmospheres are classified as oxygen deficient when the fall below ____ percent oxygen.

19.5

200

A hose clamp should be placed approximately _____ Feet from a coupling and on the _____ side of the coupling.

5 Feet   /    Incoming (water supply)

200

NFPA standard for occupational safety

NFPA 1500

300

What are the three sides of the fire triangle?

Heat, fuel and ignition source

300

Marking items such as hydrants, FDC's and Knox box locations on a blue print is called what?

A pre-incident plan

300

_____ is the number of people an individual can effectively supervise.  The optimum number of persons is ___ and the with the limits generally set at ___ to ___.

Span of Control

5


3 to 7

300

Diking, damming and diverting are _____ options available for _____ control.

defensive / spill

300

The parts of an extension ladder that prevent the fly section from being overextended are called?

Stops

300

Standard of live fire evolutions

NFPA 1403

400

What is an inspection hole?

A triangular cut to check for fire behavior

400

What type of construction are modern homes?

Type V

400

The _____ serves to coordinate the flow of personnel into and out of the fire area with the Incident Commander.


 Accountability Officer

400

What level of PPE is fully encapsulated?

Level A

400

4 basic groups for forcible entry tools are what?

Cutting, Pushing/pulling, prying, striking

400

Standard on PPE

NFPA 1977

500

What are some warning signals of a possible backdraft?

-Black Smoke turning greyish yellow.

-Little to no visable flame

-Smoke stained windows

-Smoke leaving the building and being drawn back in.


500

A type of wood framing that has vertical channels going from floor to floor allowing a fire to travel uninterrupted is _____________.

Balloon frame construction.

500

The process of dividing large jobs into smaller jobs to make them more manageable is described as:

Division of Labor

500

The radiation that is least dangerous as a threat to external portions of the body but is very dangerous if ingested or inhaled is:

Alpha

500

What type of extinguisher may be required to extinguish a restaurant kitchen fire involving the fryers?

Type K

500

NFPA standard for HazMat and weapons of mass destruction?

NFPA 1072

600


The Three most important factors that affect wildland firefighting area?


Fuel, Weather, and Topography

600

At _____ degree F steel will begin to elongate, a 100 FT beam at this temperature will expand about ____ inches

1000 degrees

9.5 inches


600
What are the 4 major sections of the command organizational structure?

Finance, Logistics, Operations, Planning (FLOP)

600

Toxicant's that can temporarily, sometimes severe, cause inflammation to the eyes, skin or respiratory system.

Irritants

600
What are your 5 types of extinguishers?

A - Class a combustibles

B - Flammables Liquids

C- Electrical energized fires

D - Flammable Metals

K - Commercial kitchen

600

NFPA standard on wildland fires

NFPA 1051