Chapter 22
Chapter 22 (AGAIN)
Chapter 4 & 5
Chapter 6 & 12
Chapter 13,3& 7
100

What does FACP stand for and what does it contain?

Fire Alarm Control Panel; electronics that control and monitor the fire alarm system 

100
What is ESFR?
Early Suppression Fast Response
100

What does this acronym stand for?

Oh My Turnouts

outer shell, moisture barrier, thermal

100

What does a bright white light fire mean?

magnesium fire

100

What is the PSI for fog nozzles?

100 psi

200

FCS can include what?  (6)

- FACP

- Smoke control station

- Fire pump status indicator

- Emergency elevator controls 

- Emergency communication system

- Spare sprinkler and fuse; building plans and system diagram 

200

What is held in by two levers that hold water flow; when heated the links to melt 

Fuseable link 

200

Fire fighters should use hearing protection if decimals reach __ in US and __ in canada

90; 85

200

What is a class D extinguisher used for?

combustible metals, magnesium (yellow D); dry powder

200

What is type 1 construction?

fire resistance; reinforced concrete, precast, protected steel like twin towers, high rise 

300

What are the 4 signal types?

audible, visual, textual, tactile

300

used typically in dry systems and deflects downward; hemisphere pattern 

upright 

300

what is the first stage of a fire called?

incipient; beginning of fire small confirmed

300
what is a class B fire extinguisher used for?

Gas (red B); dry chemical 

300
Myelon, polyester, regular, polypropylene, water resistant, long lasting, light weight are all what types of fiber?

synthetic 

400

What are the 3 types of supervising station alarm systems?

proprietary: protects large commercial, industrial, high rise and groups of commonly owned facilities

central station: monitored by contracted services at a receiving point

remote receiving: directly connected to dispach

400

valve is held in by plunger and a pellet made of solder. solder melts releasing plunger 

chemical pellet

400

what stage of the fire is this?

decrease of combustion (fire going out)

decay

400

What hose is this?

truck to fire 50 ft sections

attack hose 

400

350 gpm or more, 2 1/2 to 3 inch, 80-100 psi 

master stream 

500
What detector is the fastest to respond?

Flame detectors 

500

hidden under a removable cover, releases under certain amount of heat 

conseald

500

what does UEL and LEL stand for?

upper explosive limit; lower explosive limit

500

what is the NFPA national standard threads per inch?

7 1/2

500

min line 1 1/2 to 3 inch; 40 to 350 gpm

hand line