The Pits of Penetration
The Hydromatic
Lipo the hungry Hippo
What a development
glow worms
100

Penetrant oils can cause explosion if they come into contact with liquid oxygen, Developer materials can absorb and retain moisture resulting in corrosion and Penetrant residue in flaws seriously affect weld quality if not removed prior to welding, are all good reasons to do this very important step

What is post cleaning

100

This method needs engineering authorization before being used

What is  Method A water washable

100

This method is highly sensitive and can detect small tight discontinuities

What is Method C: Solvent removable

100

These can cause explosion if they come into contact with liquid oxygen

What is Penetrant oils

100

Developer materials can absorb and retain moisture resulting this detrimental condition if not properly removed after a penetrant inspection

What is Corrosion

200

Temperature can reach up to 750°F using this equipment, so.. Do not operate with cracked, chipped, ill-fitting filters and Do not operate if flammable vapors are present.

What is UV-A lamps

200

precautions should be taken because this is harmful to the Eyes and skin

What is Ultraviolet radiation

200

This method is also known as Lipophilic or oil based

What is Method B

200

This method requires a pre-rinse before the remover step

What is Hydrophilic method

200

This method has a tolerance to excess removal time

What is Method D Hydrophilic

300

solvent is the way this method is removed

what is Method C

300

2 minutes is the Emulsification dwell time for this FPI method

What is Method D:Hydrophilic 

300

Using method B , the emulsification dwell time shall not exceed this limit

what is 5 minutes

300

This improves visibility of entrapped penetrant

What is Developer

300

the part temperature shall not exceed this when drying parts after penetrant application

What is 140 degrees F

400

contrast between an indication and its background is improved by the use of this

What is Developer

400

 If  a Discontinuity interferes with the part’s usefulness , it is classified as this

What is a defect

400

In-service, processing, Inherent are all examples of this

What are classifications of discontinuities

400

This is rounded dot indications, common to cast parts and welds, and not a defect unless extensive enough to cause weakness of structure

What is Porosity

400

This is the number of samples that must be taken from new batches of penetrant, emulsifier, remover and developer?

What is Two

500

Because this systems materials are not subject to reuse or contamination during use ,it does not require a 7 day system performance test

What is Solvent removable penetrant systems

500

This is an interruption in normal configuration of a part which may or may not affect the usefulness of the part

What is a Discontinuity

500

Prior processing or rework, the Geometry of part, or Improper processing can cause this

What is an inspection indication

500

This dwell mode is the preferred mode

What is Drain mode

500

While using UV-A lamps This What type of glasses shall be worn

What is UV filtering safety glasses