Optiflow+ Duet is reshaping respiratory support with this type of nasal high flow therapy
What is Asymmetric nasal high flow
How many sizes of masks are there in the Nivairo line?
What is four. XS, S, M and L.
The type of water produced by any F&P humidifier
What is water vapour
The flow range of the Airvo 3
What is 2-70 LPM
Where are the global Fisher & Paykel headquarters located?
Where is New Zealand
Optiflow+ Duet enhances these two components of respiratory support
What is increasing dead space clearance and increasing pressure
What is TubeFit?
What is a feature designed to help maintain an effective seal around the nasogastric and orogastric tubes.
This component of the F&P 950 Humidifier System is integrated into the inspiratory circuit.....instead of external like the MR850 humidifier system.
What is a temperature probe
The Airvo 3 is equipped with this new feature that allows for patient mobilization throughout the hospital, for up to 40 minutes.
What is a battery
What is our "bridge free" mask called?
What is Visairo
What do you do if your patient has an NG tube?
What is size down
What is RollFit?
What is an auto adjusting seal designed to help fit the unique contours of the bridge of the nose which is why the mask should sit lower on the nose
What are the two main features of the neonatal invasive circuit that differs the 950 circuit from the 850 circuit?
What are the length (0.5 m longer) and Thermadept (dual zone heating)
The two oxygen input methods available on the Airvo 3
What is high pressure oxygen input and low pressure oxygen input
How frequently do we recommend changing the Airvo circuit on a patient?
What is every 2 weeks.
The Optiflow+ Duet interface can reduce this symptom that patients in acute hypoxemic respiratory failure often present
What is reduce work of breathing
Where do we size the mask to on the face?
What is the lower lash line and right below the lower lip SMALL IS THE NEW MEDIUM!
How many temperatures are available when the F&P 950 Humidifier is in Adult Mask Mode?
What are 3: 27,29, and 31
The highest FiO2 that can be delivered without an alarm on the Airvo 3
What is 100% !
This is the name of the Airvo unit used at home.
What is myAirvo.
The asymmetric design of the Optiflow+ Duet interface (unidirectional flow) results in this positive feature for patient comfort and compliance
What is a quieter nasal high flow interface
Should the forehead "T" touch the forehead?
What is NO. There should be at least one finger space between this and the forehead.
This adapter is only required for a dual limb setup on the F&P 950 and is the only external cable needed with this humidifier
What is the F&P 950 expiratory heater wire adapter
This is an alternative to the red disinfection kit when cleaning the Airvo 3
What is the replaceable elbow.
Where is the Fisher & Paykel office in Canada located?
Where is Laval, Quebec. (will accept Montreal or Quebec)