Are bars allowed on sleeping room windows in a non sprinkled apartment?
14.15.2 Where approved on secondary means of escape, security bars, grates, grilles, or similar devices shall be equipped with approved release mechanisms that are releasable from the inside without the use of a tool, a key, special knowledge, or force greater than that which it takes for normal operation of the door or window.
What minimum distance shall patio heaters be located from exits of an assembly occupancy?
5ft. 69.3.13.1.3
What is the maximum occupant load of a 3000 square foot Type 5B building classified as H-2, with only one exit?
3 Table 1006.2.1
What district am I standing in?

2nd District
What type of sprinkler system is shown in the picture?
Wet-pipe system
Dead-end fire department access roads in excess of _________ in length shall be provided with approved provisions for the fire apparatus to turn around.
18.2.3.5.4 Dead Ends. Dead-end fire department access roads in excess of 150 ft (46 m) in length shall be provided with approved provisions for the fire apparatus to turn around.
Where panic or fire exit hardware is installed, the maximum unlatching force shall not exceed 20 pounds. T or F
False(15 pounds) 1010.1.10.1(4)
Which type of sprinkler head is shown in the photo?

Recessed Pendent
Which mammal has the most powerful bite in the world?
Hippo
The manufacture, transportation, storage, sale, and use of explosive materials shall comply with ________________.
65.9.1 The manufacture, transportation, storage, sale, and use of explosive materials shall comply with NFPA 495, Explosive Materials Code, and NFPA 498, Standard for Safe Havens and Interchange Lots for Vehicles Transporting Explosives.
What is this and where must it be located?

Spare head box and adjacent to the riser.
How many players can be on a major league baseball opening day roster?
26
What is the minimum clear distance required around a fire hydrant?
36in 13.1.5
According to 2015 IBC, any A-2 over _______ occupants is required to have an automatic sprinkler system.
99 903.2.1.2