Fire Code
Building Code
Know Your District
Fire Suppression Systems
Misc.
100
Are bars allowed on sleeping room windows in a non sprinkled apartment?
14.15.2 Where approved on secondary means of escape, security bars, grates, grilles, or similar devices shall be equipped with approved release mechanisms that are releasable from the inside without the use of a tool, a key, special knowledge, or force greater than that which it takes for normal operation of the door or window.
100
A college classroom with an occupant load of 37 is classified as which use group?
Business Group B 304.1
100
Bowman Field is located in which district?
4th
100
Name the four main types of sprinkler systems.
Dry Pipe Wet Pipe Deluge Pre-Action
100
How many U.S. states border the Gulf of Mexico?
5
200
What minimum distance shall patio heaters be located from exits of an assembly occupancy?
5ft. 10.11.7.3
200
What is the maximum occupant load of a 3000 square foot Type 5B building classified as H-2, with only one exit?
3 Table 1015.1
200
What district am I standing in? Image 1
2nd District
200
What type of sprinkler system is shown in the picture? Image 2
Wet-pipe system
200
The average person does what 13 times a day?
Laughs
300
Dead-end fire department access roads in excess of _________ in length shall be provided with approved provisions for the fire apparatus to turn around.
18.2.3.4.4 Dead Ends. Dead-end fire department access roads in excess of 150 ft (46 m) in length shall be provided with approved provisions for the fire apparatus to turn around.
300
Where panic or fire exit hardware is installed, the maximum unlatching force shall not exceed 20 pounds. T or F
False(15 pounds) 1008.1.10.1(4)
300
1225 S. 15th is located in which fire district?
2nd
300
Which type of sprinkler head is shown in the photo?
Recessed Pendent Slide 4
300
It is illegal in California to buy a mousetrap without what?
A hunting license
400
The manufacture, transportation, storage, sale, and use of explosive materials shall comply with ________________.
65.9.1 The manufacture, transportation, storage, sale, and use of explosive materials shall comply with NFPA 495, Explosive Materials Code, and NFPA 498, Standard for Safe Havens and Interchange Lots for Vehicles Transporting Explosives.
400
What is the maximum percentage of a building an incidental use can occupy?
10% 509.3
400
What company is located at 1328 S. Preston, and which district is it in?
E-15 2nd District
400
What is this and where must it be located?
Spare head box and adjacent to the riser. Slide 5
400
How many players can be on a major league baseball opening day roster?
25
500
What is the minimum clear distance required around a fire hydrant?
13.1.3 Obstructions shall not be placed or kept near fire hydrants, fire department inlet connections, or fire protection system control valves in a manner that would prevent such equipment or fire hydrants from being immediately visible and accessible.
500
An R-2 occupancy with fuel-burning appliances shall be equipped with single-station carbon monoxide alarms that comply with _________ and are installed and maintained in accordance with what ____________.
UL 2034, NFPA 720 908.7
500
Audubon Country Club is located in which fire district?
4th District
500
According to 2012 IBC, any A-2 over _______ occupants is required to have an automatic sprinkler system.
99 903.2.1.2
500
Who was the U.S. president during World War I?
Woodrow Wilson