Pumps
C.C
DWV
Potable Water
Storm
100

How many gallons per day do 100 Turkeys require?

22 gallons

100

What does PVB stand for?

Pressure vacuum breaker

100

Minimum size of water seal on an interceptor acting as a trap.

38 mm 

2.4.5.1,5

100

What is the maximum length of connector used with a 3/8" supply pipe.

750mm

100

What is the rainfall intensity in Neepawa?

28 mm per 15 minutes

200

How many feet would the suction head be if a compound mercury gauge read 18.9" HG

21.42'

200

How many hours is a Cross-Connection certification course?

minimum 30 hours

200

A vent pipe that serves an oil interceptor and is located outside a building shall not be less than _____ in areas that may be subject to frost closure. 

NPS 3" 2.5.5.2,5

200

What is the minimum size water service pipe for a mobile home?

3/4"

200

The placement of rainwater leaders depends on 2 factors what are they?

Building and roof shape, size of leader

300

What kind of adapter is required when installing a Jet pump into a deep well.

A two pipe pitless adapter.

300

Bypass arrangement and jumper connection are examples of?

Potential cross connections

300

Max FU's draining into a 5" stack.

1400 FU's

2.4.10.6, A

300

What is the hydraulic load for a dental unit for public use?

1 FU

300

When calculating a combined building sewer and your total FU's are less that 260 what is your total in big L's.

2360 big L's

400

How many minutes is the peak period used to size the pump for a residence.

7 minutes

400

What recommended cross connection device would be used for a water softener.

DCAP

400

Where may air admittance valves not be installed. 

Supply or return air plenums or in locations subject to freezing.

2.5.9.3,1

400

What is the table for sizing urinals with direct flush valves?

2.6.3,2-B

400

What is the reason we don't connect fixtures to rain water leaders?

What is to prevent storm water from backing up into the system during a storm. or

To not pollute clear water waste.


500

What are the rights given to a property owner to use the water that flows through or past the owners property?

Riparian rights.

500

The CAN/CSA manual for Backflow prevention requirements is?

B64.10-01

500

The developed length of a building sewer between the building and the man hole the building sewer connects to shall not exceed. 

75 m

2.4.7.2,3

500

Tank type water closets shall be provided with a back-siphonage preventer in conformance with code___?

2.2.10.10.(2)

500

All roof drains shall be installed ______ below roof level.

1/4"