What is the warranty on an 1800 unit, does this differ on an 1800XTSx?
1800s have a 5 year warranty for manufacturing defects.
1800XTSx is 2 years on the system, 5 years on the compressor.
What is an HA2 alarm mean? Common causes?
The temperature at the condenser coils is too hot. Over 130/140 depending on the unit.
restrictive airflow, dirty filter, failed fan/controller, hot ambient.
"I am getting an HA alarm, but my display is ready 55 degrees. I did just change my settings, can you help?"
What stands out? What should we check?
Check the ALU setting per the manual.
I want to put my Le Cache Cabinet in a garage that gets to 100 degrees, is this okay?
NOPE. 95 peak ambeint.
Can a customer return a gift? What will the recipient get once the order is returned?
Yes, they will get a store credit.
Where can I find cut sheets, or install information on my CellarPro unit
Under specs and resources on our site. Manual will include everything this should need
What is an HA alarm?
Cellar is too hot. Over 70 for over an hour.
"I am getting erratic readings but my temperature is normal in the cellar"
What stands out? What should we check?
YES, but would need compressor heating (good for 40-20 degrees) and a fan cycling switch (good for 20 to -20 degrees).
I am ordering from Alaska, and my order is for non-oversized items. How do I use the free shipping promotion?
Free shipping only applies within the continental US.
Do we have techs we can recommend?
No, we do not recommend techs, but we can share names of those we have a record of working on out units.
What is a CA alarm?
The condensate pump overflow
level has been reached, and the
cooling unit is automatically shut
down.
"My cabinet is 68 degrees, but my unit is reading 50 degrees, what is happening?"
What stands out? What should we check?
Is the unit icing, is the cold side fan blowing?
I have a 2000VSi with your standard display. I want a networkable display. Can I add this?
Yes, but not in the field. The unit would need to come back for retrofitting.
I have a Legacy wine opener that looks like your Rogar openers. Will those parts work?
Our parts may work for other openers but we are unable to guarantee it. They are designed for authentic Rogar openers.
If a cabinet is damaged in transit, what should we do?
get pictures, and send the appropriate solution.We can repair in the field, replace a part or all of the cabinet depending on extent of damage.
LA means the cellar is too cold (below 45)
LA2 means the intake outside the cellar is too cold, below 40.
"My unit is triggering an LA alarm, but my cellar is 55 and reading 55 on the display."
What may be happening?
Lets check the ALL setting per the manual.
NO, Houdini units need the bottle probe to measure temperature which is not compatible with networkable displays.
1800 units can not use networkable displays.
I have glassware I ordered from you that was delivered last week but I need to return them. I threw away the packaging the glasses came in. If I package them safely, can I return them?
No, all returns require the items to be in new and unused condition with the original packaging.
How do we test for a gas leak on a Winekeeper?
Check all connections with water and look for bubbles. Bubbles mean gas escaping. Is the thumbwheel tightened?
What is a DEF alarm?
DEF is not an alarm! It indicated the unit is in defrost mode. Customer will often think its an alarm, but it is normal.
I have a split CellarPro unit. My evaporator is off, and its icing up. It sounds like the condenser is running.
What stands out?
I see the 1800XTS has cold airflow on the front and underneath the unit. Can I put the unit on top of the cabinet (outside of the cabinet)?
Yes, would need out front intake hood.