Definition of Backflow

 

 


The unplanned reversal of flow of water or mixtures of water and contaminants into the water supply system. See back-siphonage and back-pressure.

100

Definition of Cross connection

Any actual or potential connection between a potable water supply and a source of contamination.

100

Definition of Non-return valve 

A valve that permits flow in one direction but prevents a return flow and is part of a hot or cold water system.

100

Definition of Valve vented storage water heater 

(Also known as an unvented storage water heater.) A storage water heater in which the required venting to the atmosphere is controlled by a valve.

100

Definition of Back-pressure  

 A backflow condition caused by the downstream pressure becoming greater than the supply pressure.

200

what are the requirements for the gap of an air gap

be the greater of 25 mm or twice the supply pipe diameter

200

what are the three cross connection hazards 

low, medium and high

200

what is the pressure 1 meter of head in KPa

9.81 KPa

200

drainpipes are required for hot water cylinders of more than what capacity

45 ltr

200

a hot water cylinders control thermostat should be set know less than what temperature to prevent the growth of legionella bacteria

600c

300

what is the temperature at an outlet of any sanitary fixture at a institution for people with physical disabilities 

45 0c

300

the temperature of an electric and gas storage water heater shall be controlled by a ? 

Thermostat

300

what is the acceptable flow rate and temperature of a shower

0.1 at 420c

300

which two places can hot water cylinder vent pipe terminated

outside the building

over the water tank supplying the storage water heater

300

what are the installation requirements for a Double check valve

there are none

400

how much cold-water storage is required for buildings with the classification of community care

50 ltr

400

how far away can a pressure relief valve be located from a hot water cylinder

1 meter

400

the pressure of a working sanitary fixture / appliance shall be no less than how much KPa 

30

400

the working pressure at a sanitary fixture shall not be more than how many meters of head

50

400

the open vent for a storage water heater shall have a minimum standing water level of ? above the highest outlet 

30 meters

500

what is the clearance for above the highest outlet served by a Atmospheric vacuum breaker 

150 mm

500

when it comes to water storage heaters what is the other name for a Free outlet system

push through 

500

A RPZ (Reduced pressure zone devices.) the relief valve outlet should not be instilled less than what measurement above the surrounding surface

300 mm

500

what is the minimum capacity for a solar water heater per square meter of collector area 

50 ltrs

500

where roof penetrations are greater than what measurement is additional framing required 

200 mm