Definitions
General Regualtions
Fixtures
Sanitary Drainage
Vents
100

The Unobstructed Vertical Distance through the Free Atmosphere between the Lowest Opening from any Pipe or Faucet Supplying Water to a Tank, Plumbing Fixture, or other Device and the Flood Level Rim of the Receptacle

What is Air Gap (Water Distribution)

100

Interval that 1" CPVC Pipe in the Horizontal shall be Supported

What is 3'

100

Requirement for a Single (Person) Use Bathroom

What is a Locking Door

100

Separate Drainage and Vent System of an Approved Corrosion Resistant Material 

What is a Chemical Waste System

100

Minimum at which a Vent shall extend through a Roof

What is 6"

200

Th Undesirable Reversal of Flow in a Piping System

What is Backflow

200

Sheathing or Wrapping on Piping Minimum Wall Thickness

What is 0.025"

200

Minimum Distance between Plumbing Fixtures

What is 30" Center to Center

200

Slope of 3" to 6" Drainage Pipe

What is 1/8"

200

Maximum of 8 Fixtures Connected to a Horizontal Branch Drain being Vented 

What is a Circuit Vent

300

The Lowest Part of a Drainage System that Extends 30" Outside of the Building

What is the Building Drain

300

The Level at which Trenches Shall not Break

What is the 45* Bearing Plane

300

Max Discharge Water Temperature for a Bidet

What is 110*

300

Serves a Building Drain and has a Gas-Tight Cover

What is a Manhole

300

A System that shall not Serve Fixtures Other Than Floor Drains, Sinks, Lavatories, and Drinking Fountains

What is a Combination Waste and Vent System

400

Waste Discharged from Lavatories, Bathtubs, Showers, Clothes Washers, and Laundry Trays

What is Gray Water

400

Requirement for all Bathrooms

What is Illuminated and Ventilated

400

Fixture with a Drain Not Less than 2"

What is a Floor Drain

400

A Water Closet (1.6 GPF), Lavatory, Bathtub or Shower, including or excluding a Bidet, and Emergency Floor Drain or Both with a DFU Value of 6

What is a Bathroom Group

400

Max Developed Length from a Sanitary Stack that a Water Closet Connection shall be made

What is 4'

500

Any Pipe or Fitting that makes an Angle Greater than 45* with the Horizontal Plane 

What is a Vertical Pipe

500

Minimum Time For Testing

What is 15 Minutes

500

Shall be a "Gravity Return System" 

What is Steam Condensate Return

500

Minimum 18" in Diameter x 24" in Depth

What is a Sump Pit

500

Every Plumbing System shall have at least 1 that extends to the Outdoors

What is a Stack Vent or Vent Stack