Ethics
SOPs
Collection Exceptions Common
Quality
Common practices/Errors
100

The immediate and long-term risks of sharing login credentials in a healthcare setting.

What is the loss of transparency & accountability?

100

An insufficient bottle of 56 mL is collected and given to processing and no samples are collected because the unit will be destroyed. True/False. 

What is False? 

100

This collection exception code requires you to document whether or not an RBC loss has occurred with the collection. 

What is Underdraw codes?

100

Required to be worn when we are performing our job duties in a production area. 

What is PPE? 

100

In-between processing bottles you can leave the cannula/tube drawers open. 

What is False?

200

How could Rob have handled the need for payment overrides without violating IT policy? 

Reach out to another manager or member of CLT.

200

These three things are required to be documented when you perform a restick. 

What is......

1. Restick exception code 

2. Second needle 

3. Restick phlebotomist 


200

A condition where the plasma is red, pink, or cloudy and means we can't return the donors cells. 

What is hemolysis? 

200

These three things are required to be documented on the control vials for morning opening?



What is the opening date, expiration and initial and date of employee who opened vials?

300

Why is individual accountability and traceability so important in regulated environments? 

Allows us to make decisions on product suitability and corrective actions 

300

A supply issue where we have to keep a supply, give to processing to quarantine and we notify MGMT/QA. 

What is a defective softgood? 

300
These needs to be checked weekly for training purposes. 

What is GTP? 

300

According to the 21 CFR 172.615, this activity is prohibited to prevent contamination or potential ingestion of harmful substances.

What is chewing gum?

400

What could happen if an error or adverse event occurs when someone logs in under another person's credentials?

* Wrong person could be blamed 

* Never find the cause of the error/incident

* Both employees get in trouble 

400

This deviation occurs when an employee inputs the incorrect volumes on the Aurora Xi. 

What is Optimized Nomogram?

400

The dimensions of a bruise that would prevent a donor from donating and require a CMS to document a DAER.

2 inches by 2 inches or greater.

400

You should NOT do this if the machine reads the bottle is an Overdraw. 

What is not re-weighing the bottle? 

500

Are there ethical justifications for deviating from IT policy if the intention is to help the team? 

* YES, because....... 

500

This serious deviation occurs when an employee inputs the incorrect weight, hematocrit, the bottle is not positioned correctly in the holder, or has something touch it during donation.

What is an Overdraw?

500

A set of infection control practices used to prevent transmission of bloodborne pathogens by treating all blood and bodily fluids as potentially infectious.

What are Universal Precautions? 

500

These forms are used when a donor has a DAER on the center premises. 

What is MED-006J Donor Floor and MED-008E CMS