The price of our Standard troubleshooting & diagnostic
Bonus: It includes _______
What is $366
Bonus: This covers the troubleshooting & Minor repair of an electrical problem on ONE CIRCUIT ONLY. This task includes an unlimited amount of time to determine the problem and the replacement of any one small part to restore power (outlet, switch, or standard breaker). In the event new wiring has to be installed an additional flat rate task will be required.
Distance between two ground rods
Code requires 6'
Sparky Standard is 8'
Name 2 components used to identify the grounding system for an inspector
*DAILY DOUBLE*
What are:
1. 2" PVC Coupling
2. Flag
Provide a Feature of our smoke detectors
Dual-sensing (Photoelectric and Ionization)
10yr sealed battery backup
Interconnected
Integrity of electrical equipment and connections
What is 110.12(B)?
Standard Hot Tub circuit up to 30'
Bonus: It includes ________
& does not include _______
What is $1347
Includes nothing additional
Trenching, permits, disconnect, and gfci breaker are all at an additional fee or customer supplied.
Minimum conductor size for 100a residential service
What is #4 AWG copper
What size copper feeder is required for a 200a commercial service?
3/0 copper
Benefits to a home redevice
All new TR/WR devices
some specialty devices are included
"Shepards hook" connections not "backstabbed"
all connections done by certified electricians
Table for wire ampacity
What is 310.16?
Main panel surge protector
Bonus: Describe some FAB's
What is $826
Feature: Audible alarm, LED indicator, lowest clamping voltage available,
Advantage: up to 30% additional lifespan for appliances
Benefits: $50,000 connected equipment coverage
The smallest wire size that can be phased
#4 AWG
Duct Seal is required
What is When a conduit penetrates between two different temperatures?
What surge protectors come in a standard surge package
Panel
Secondary
Coax or Cat 5
Arc-Fault Circuit-Interrupter Protection in Dwelling Units
What is 210.12 (A) - (D)?
Single pole specialty breaker (gfci or afci)
Bonus: Do or do not Discount for more than 1
What is $301
Bonus: Like smoke detectors, the more that are needed the cheaper each gets
Minimum running KW size for a portable gen. install
(Inlet with main interlock)
10KW running watts or larger
Solve the following:
1. The maximum wattage for a 120v 20a circuit
2. The amps for a 9600w AHU
voltage x amperage = watts
1. 2400w maximum
watts/voltage = amps
2. 40a
Benefits of Cutler-Hammer or Square D QO products
All copper busbar
Lifetime manufacturers warranty on panel and breakers
Trip-indicate window on breakers
Table showing standard size circuit breakers
What is 240.6(A)?
Standard ceiling fan
Bonus: Specialty ceiling fan and differences
What is $147 or $245
Bonus: $302 - $364
Height of the ceiling, Light kit or no, remote or pullchains
Minimum wire size for an A/C with the following specs:
What is #10 AWG
Bonus: why?
#10 conductors you can fit in 1/2" EMT
What are 5?
Advantage or benefits to using Mister Sparky
Most answers accepted
Surge protection
What is 230.67 (A) - (D)