Regulations & Agencies
Units
Math
Packaging
Values & Limits
100

To be classified as a __________, a material must equal or exceed its RQ value as listed in Appendix A to 172.101 as defined in 172.8.

hazardous substance

100

The _______ is the unit of measurement in the SI system for expressing the number of disintegrations per second emitted by a radioactive substance.

Becqurel (Bq)

100

Convert 5 rem to mSv:

5 rem x 0.01 Sv/rem = .05 Sv or 50 mSv

100

The contents for a __________ must be listed on the radioactive label contents line as required by 172.403(g)(1)

Radioactive materials package

100

What is the A1 value for Cs-137?

2.0 TBq

The A1 value for Cs-137 is obtained from the table in 173.435 and is found to be 2.0 TBq as listed in column 3 of the table for Cs-137.

200

Radioactive material is assigned to what DOT hazardous material class?

Class 7 in accordance with 173.2

200

What units are used to express the value for activity concentration for exempt material?

Bq/g. 


The units to express activity concentration for exempt material as listed in Table 173.436 are Bq/g.

200

What is the RQ sum of the fractions for a package that contains 5.0 x 10-2 GBq of Am-241, 2.8 x 10-2 TBq of Cs-137, 0.2 TBq of Co-58, and 1.0 TBq of Ni-63?

Total RQ ratio = approximately 1.7


We must calculate the individual RQ ratios for each of the four radionuclides. Ratios are determined by dividing the individual radionuclide activity by its respective RQ value, listed in Table 2 to Appendix A of 172.101.

Am-241: 5.0E-5 TBq/3.7E-4 TBq = 0.135

Cs-137: 2.8E-2 TBq/3.7E-2 TBq = 0.76

Co-58: 0.2 TBq/0.37 TBq = 0.54

Ni-63: 1.0 TBq/3.7 TBq = 0.27

Total RQ ratio = approximately 1.7 which is greater than 1; consequently, the package contains a RQ.

200

An "____" is designated in the regulations by a lower-case Roman numeral in parentheses.

Item

200

One of the primary parameters that impact the type of package required to transport a given quantity of radioactive material is:

Quantity.


The quantity, and more specifically the quantity as it relates to the applicable "A" value, primarily determines the type of package required to transport a given quantity of radioactive material.

300

Which agency approves the design and use of Type B packages?

NRC


The design and use of Type B packages are approved by the NRC, and the DOT authorizes the use of Type B packages for Type B quantities in accordance with 173.416.

300

The ______ is the unit of measurement in the SI system for expressing the dose equivalent.

Sievert (Sv)

300

A package contains four radionuclides, and you are tasked with determining if the package contains a reportable quantity. The activity of the four radionuclides represent 20%, 10%, 49%, and 28% of their respective RQ values. Does this package contain a reportable quantity?

Yes


The sum of the RQ ratios for all the radionuclides in the package exceed 1 (0.20 + 0.10 + 0.49 + 0.28 = 1.07). 

Per note 7 of Appendix A to 172.101: A package contains an RQ of a hazardous substance when the sum of the ratios for the radionuclides in the mixture equals or exceeds one.

300

The hierarchy notation utilized in the 49 CFR regulations follow this scheme:

Part – Section – Paragraph – Subparagraph – Item – Subitem

300

What is the limited quantity limit for normal form Po-210? 

2E-5 TBq


The limited quantity limit for normal form Po-210 is 10-3 A2. The A2 value for Po-210 is 2E-2 TBq. Therefore the LQ value for Po-210 = 2E-5 TBq.

400

Which part of 49 CFR of the DOT regulations pertains to shippers and provides the general requirements for shipments and packaging?

Part 173 is titled: "Shippers-General Requirements for Shipments and Packages"

400

Which conversion factor is used to convert curies into becquerels?

To convert curies to becquerels you multiply the number of curies by 3.7E10 dps per curie to obtain the number of becquerels.

400

What is the limited quantity limit for normal form C-14?

3.0 E-3 TBq.


The activity limits for limited quantities are provided in Table 4 of section 173.425. For normal form solid radioactive material, the limited quantity limit is 10-3 of a material's A2 value. The A2 value for C-14 obtained from the table in 173.435 is found to be 3.0 TBq. Therefore, the limited quantity limit for C-14 is 10-3 x 3.0 TBq = 3.0 E-3 TBq.

400

The most common example of a DOT Specification 7A Type A package is a ___________.

55-gallon metal drum

400

______ radioactive material documentation must contain the information specified in 173.476 that covers design, testing and related documentation. Section 173.476(c)(1) and (2) pertain to the design documentation that must be available.

Special form

500

Subchapter C of 49 CFR is titled: "______________" and contains the regulations associated with the transport of hazardous materials.

Hazardous Materials Regulations

500

Which conversion factor is used to convert rem into sieverts?

To convert rem into sieverts you multiply the number of rem by 0.01 to obtain the number of sieverts.

500

Convert 50 mCi of Cs-137 to GBq

50 mCi x 37 MBq/mCi = 1850 MBq or 1.85 GBq

500

Packaged and unpackaged Class 7 (radioactive) material must be ___________ to prevent shifting of lading under conditions normally incident to transportation.

Braced

500

The derivation of the "_" values is based on the IAEA's "Q" system found in Appendix I of SSG-26.

A


The "A" values are based upon the ICRP biokinetic dose modeling parameters to include uptake factors, the type of radiation, and the energy of the emitted radiations. The derivation of the "A" values is based on the IAEA's "Q" system found in Appendix I of SSG-26.