This road intersects with blankenship and s. frusha.
What is Porter st. ?
100
cast iron
Most fire hydrants are made of: (605)
100
green
According to the NFPA®, ___ hydrants indicate a flow of 1,000 to 1,499 gpm (3 785 L/min to 5 675 L/min). (609)
100
Drawing water from a static source to supply a pumper
What is the definition of drafting? (610)
100
Combination systems (DAILY DOUBLE! DAILY DOUBLE! DAILY DOUBLE!)
Which method of moving water is used in the majority of communities in North America? (597)
200
What is the road across from stacey on fifth st.
What is Allen st.?
200
water hammer
Closing a hydrant too fast may cause a sudden increase in water pressure called: (605)
200
500 to 999 gpm (1 900 L/min to 3 780 L/min).
According to the NFPA®, orange fire hydrants indicate a flow of: (609)
200
24 inches (600) mm
A minimum of ___ inches (mm) of water above and below a hard intake strainer is usually needed for it to function properly. (611)
200
Total dependence on pumps
What is a disadvantage of direct pumping systems? (595)
300
This road intersects with Whitney dr.
What is Chase st. ?
300
Wet-barrel
Which type of hydrant is usually installed in warmer climates where prolonged periods of subfreezing weather are uncommon? (607)
300
Dry-barrel
Which type of hydrant has a main valve located below the frost line that prevents water from entering the hydrant barrel? (605-606)
300
Hauling water from a supply source to portable tanks
Which of the following is the definition of a water shuttle? (612)
300
Gravity systems (DAILY DOUBLE!!!!!!!DAILY DOUBLE !!!!!!!!!!!)
method of moving water uses a primary water source located at a higher elevation than the distribution system and delivers water to the system without the use of pumps? (596)
400
This is a dead end off Oneal st. (DAILY DOUBLE!)
What is Peggy ln.
400
drain hole
When a dry-barrel hydrant is closed after use, the remaining water empties through a: (606)
400
1,500 gpm (5 680 L/min) or greater.
According to the NFPA®, light blue hydrants indicate a flow of: (609)
400
Apparatus with greatest pumping capacity (DAILY DOUBLE!)
Which apparatus should be located at the water source? (616)
400
6 inches (150)mm
In residential areas, mains should be ___ inches (mm) in diameter. (599)
500
Eddy rd. intersects with what roads?
What is Kerry st. and Cathy dr.
500
a quarter-turn (DAILY DOUBLE!!!!!!!DAILY DOUBLE !!!!!!!!!!!)
When ensuring that a dry-barrel hydrant is draining correctly, close the main valve by turning the step nut clockwise until resistance is felt, then turn it ___ counterclockwise. (607)
500
every other intersection.
A basic rule is to locate a hydrant at ___ intersection. (607)
500
Floating strainers
Which kind of strainers can draft water from more shallow sources? (611)
500
no more than three hydrants.
!!!!!!!!!!!Daily Double!!!!!!!!!!!
Proper valve spacing is necessary so that no more than ___ fire hydrants must be closed off while a break in a main is being repaired. (603)