Pipes
Hi-flow storage
Clarifiers
Pumps
HRDT Sampling
100

Jackson Avenue Pipe, West Side Interceptor, East Side Interceptor, Hallowell Station

What pipes convey influent flow to the WWTP?

100

It stores flow from the West Side Interceptor

What is the West Side Consolidated Conduit?

100

Wait for the WSCC to fill and begin discharging to the WWTF before putting this online.

What is Clarifier #3?

100

The pumps here will shut down on the high flow alarm at the WWTF.

What is Pump Station #2?

100

The influent end of the HRDT should have a TRC of at least this much

What is 15 mg/L?

200

Monmouth, Winthrop, Manchester, Hallowell and Augusta

What are the WWTF service areas?

200

It stores flow from the east side of Augusta

What is the East Side Tank?

200

If a large storm is forecast, put another one of these online the day before the storm, 100% open, turn rake arm on, enable RAS.

What is another secondary clarifier?

200

Put these pumps in "hand" during high flow events

What are the grit pumps?

200

HRDT grab sample test parameters during secondary bypass events

What are E.coli and Total Residual Chlorine?

300

At 8.0MGD, this gate will close and the influent flow will drop while the WSCC is filling

What is the West Side Interceptor gate?

300

It stores flow from Pump Station #2 during flows greater than 8MGD

What is Mill Park Conduit?

300

During high-flow events, leave the RAS rate at this speed

What is 400 gpm?

300

During disinfection season, make sure the second one of these has come on and we are maintaining an Influent Cl2 residual of approximately 2.0 mg/L

What is the second effluent chlorination pump?

300

HRDT grab and comp samples must be analyzed when these conditions exist

What is "on days when the plant is normally staffed?"