Fires reported to which floor will have the crew utilize the stairs?
what is the 6th floor
pg.46
What is 5.
Hydraulics Manual
Which due engine abandons the rig?
Also identify what this engine is bringing to the fire.
What is the 1st due.
Hose packs, entry tool, ram, officers' bag, water can
pg.46
What is the initial response assignment?
What are 5 engines, 2 trucks, 1 squad, 1 ems, 2 chiefs, 1 EMS sup
pg. 45
This engine is responsible for water
What is the 2nd due engine
What indicates a stairwell has roof access?
How many stairwells are required in each building?
What is provided signage.
What is 1.
pg. 13
The fire load in commercial buildings typically call for this hose line to be deployed
What is the 2 1/2
pg 39
We all want to put the fire out but as the second due engine it is most important that we help the first due with what?
what is the unique about this crew compared to first due?
What is the driver stays behind to establish water.
pg.47
Vehicle fires in attached garages occur in 1 of 2 configurations. What are they?
What are adjacent and underground.
pg.41
FDC is no more than how many feet from the hydrant
What is 100 feet
newer high rises may have this installed at the lowest level terminating at an exterior exit?
What is a security gate.
pg.15 diagram.19
Crews may choose to deploy from preconnect if the fire is located here?
What is below grade and floors 1-3
pg.38
Also abandoning the rig the 4th due engine is responsible for what? And where do they stage?
What is establishing the I-rit.
It is located 1 floor below the fire floor unless below grade.
pg.49
often found at ground level to minimize the impact of contaminants these may be moved out of the building while still burning?
What are dumpsters or compactors.
pg.33
This is the term for an engine and truck positioning next to each other at the incident?
What is inside/outside method?
What are accommodation stairs ( access or convenience)
pg.14 figure 17
Personnel should refrain from using these risers unless absolutely necessary
What are hallway risers.
pg19 figure 25
When establishing water what connection do we not use?
What is the test connection?
pg.48 fig.40
What is one reason the crew may observe the floor below the fire?
What is checking for smoke and fire conditions and surveying the area to note the floor layout, contents type, mechanical room locations, window type, and presence of access stairways
pg.46
Collapse zone formula
What isY+1.5x
Some stairwells have this type of opening? and others may have these installed to help with pressurization?
What are ventilation openings and fans.
pg.12
When the officer reports fire, smoke or when deemed appropriate by other considerations.
pg.47
The 6th due engine establishes what? And what does it become?
What is the base and it becomes the parking are for apparatus.
pg.54
We consider a midrise to have how many stories or feet?
What is 3-6 stories or less than 75ft.
pg.67
The area that the aerial can reach on a given structure
What is the scrub area?