WAC 308-408C-020 Ethics—Statement of purpose.

In order to ensure the integrity and high standard of skill and practice in the home inspection profession, the following rules of conduct and ethics shall be binding upon the inspector. The home inspector must: (1) Provide home inspection services that conform to the Washington state home inspectors' SOP. (2) Provide full written disclosure, to the home inspector's client, of any business, familial, or financial relationships or other conflicts of interest between the home inspector and any other party to the transaction. Written disclosure is required prior to the client's signing of the preinspection agreement. Disclosure is required to ensure the consumer's right to freely pick a home inspector of the buyer's or seller's choice and prevent collusion between the home inspector and the parties to the transaction. Parties may include, but are not limited to, buyers, sellers, appraisers, real estate licensees, mortgage representatives, title companies, vendors and service contractors.

100

Heating/Cooling returns are not allowed in these rooms.

Bathrooms or Garages.

There should be no heating/cooling returns installed in bathrooms.

100

12 feet apart

Electrical receptacles should be located within 12 feet of each other.

100

perfectly vertical

Plumb means?

100

Z-flashing

The horizontal seam between two panel siding boards should have

200

WAC 308-408C-130 Air conditioning systems.

The inspection of the air conditioning system includes the cooling equipment; cooling distribution equipment and the operating controls.

200

Fire-rated

The door between a house and its garage.

and

The common walls between an attached garage and the home's living space.


200

At least 8 feet above.

All electrical wires should clear flat roofs by at least 8 feet.

200

18 inches above the garage slab

Gas- and oil-fired water heaters located in garages must be 18 so that gasoline vapors are not ignited.

200

J-molding

Siding flashing alongside windows is called

300

WAC 308-408C-070 Structure.

An inspection of the structure will include the visible foundation; floor framing; roof framing and decking; other support and substructure/superstructure components; stairs; ventilation (when applicable); and exposed concrete slabs in garages and habitable areas.

300

Where should the gas shutoff valve be located for each appliance?

As close as possible to each appliance

300

Which is the best conductor of electricity? Copper or Aluminum?

Copper

300

lift the float

How to test a sump pump.

300

18x24

The minimum size for the access to a crawlspace is 18x24 inches.

400

308-408C-120 Heating system.

The inspection of the heating system includes the fuel source; heating equipment; heating distribution; operating controls; flue pipes, chimneys and venting; auxiliary heating units.

400

What is a "drip leg" and where is one located?

The drip leg serves as a collection area for sediment in order to reduce the potential for clogged gas valves on burners.

400

pushing the test button

The proper way for an inspector to test a GFCI receptacle.

400

Bladders

Water pressure tanks typically have bladders.

400

You'll find these hanging at least 15 inches above the counter top.

Wall cabinets

500

WAC 308-408C-110 Electrical system.

The inspection of the electrical system includes the service drop through the main panel; subpanels including feeders; branch circuits, connected devices, and lighting fixtures.

500

oil filter and shut-off valve emerge from a basement wall

oil tank is buried outside

500

What is a sequencer on an electric furnace?

control that ensures that its individual elements do not all turn on at the same time

500

leaving solids behind

A drainpipe that slopes too much.

500

idk or iuhno!

What is - The standard answer for any code questions.