PACUs & Rooftops
VAVs & Installation
Air-Source Heat Pumps
HVAC Units
Mascots
100

Air-cooled packaged chillers utilize a(n) ___ to increase efficiency.

What is an electronic Electronic Expansion Valve

100

Rooftop VAV units are designed to produce a constant discharge air temperature of ___°F.

What is 55

100

A ___ should be the same size as the flanged opening around the outlet of the air handler and should extend at least 3' from the unit before turning or branching off into duct runs.

What is the supply plenum 

100

___ are located based on the supply air pattern desired in each space and the location of the supply ductwork.

What is Registers 

100

This is the mascot of St. Peters

What is Peacock

200

A typical rooftop single-zone unit consists of a supply fan, one or more _____, one or more stages of heating, controls, ductwork, and power connections.

What are stages of cooling

200

Many VAV system problems are caused by the improper location of the ___.

What is the Static Pressure Sensor

200

A(n) ___ is a booklet that typically offers the best way to use heat pump equipment for an application and contains specific preventive maintenance recommendations for the equipment.

What is the owner manual  

200

Forced-air heating systems consist of furnaces, ductwork, registers, grills, fans, and ___.

What is controls 

200

This is the mascot of Marshall 

What is the Thundering Heard

300

Air-cooled packaged chillers typically use ____ refrigerant and are precharged with an initial oil charge as well.

What is R-410A

300

A thermostat should not be installed in a location that is ___.

What is in the line of direct airflow from supply registers 

300

Air-source heat pump filters must be listed as Class ___ furnace air filters.

What is 2

300

___ must be located where a connection can be made to the return air ductwork.

What is Grills 

300

This is the mascot of Arizona State

What is a Sun Devil


400

Before installing a light commercial system it is a good idea to check the site for ___.

What is Access and Clearance 

400

A unit should not be operated and/or started without ___ in place, otherwise damage and/or contamination of the evaporator coil can occur.

What is air filters 

400

The two sections of a heat pump are the air handler and the ___.

What is outdoor unit 

400

___ typically operate with a temperature increase of about 80°F to 100°F.

 What is Combustion furnaces

400

This is the mascot of Northwestern

What is a Wildcat

500

For cooling, most rooftop units use a(n) ___ cycle.

what is standard DX compression 

500

A crankcase heater needs to be energized for up to 24 hr before ___ startup.

What is the compressor

500

When a return air plenum is used, the ___ must be immediately in front of the opening in the plenum to allow for the free flow of return air.

What is return air grill 

500

The ___ is the central component in a forced-air heating system.

What is a furnace 

500

This is the mascot of Texas Christian University (TCU)

What is a Horned Frog