Gas Furnaces
Heat Pumps
Electric Heaters
Troubleshooting
Trane
100
Name two fuel source of a gas-fired furnace
L.P. & Natural Gas
100
Where the heat from a heat pump is gathered
Outdoors
100

What components electric heaters energized

Sequencers , contactor , and relays 

100

If voltage is read across a fuse and it reads zero what does that mean.

The fuse is good 

100

Which thermostat reverts back to original settings when there is a lost of power to it 

624 and 724 

200
When fuel is burnt, it produces this harmful gas
Carbon Monoxide
200

In what state is the refrigerant entering in the indoor coil during heating mode 

Hot gas 

200

What is the amp draw for a 10 kw heater at 208 volts. 

48 amps 

200
How could a technician determine if a heat pump reversing valve is defective
Temperature differences (on true suction)
200

What type of metering device does a 4twr7036 condenser have 

EEV


300

Removes the flue gas from the heat exchanger chamber.

Draft motor / inducer 

300

What wires get energized in heat mode for a 2 stage Trane heat pump  

Y1 , Y2 , and G 

300

On a 15 kw trane heat kit (240) , how many amps does only w1 pull if staged properly 

40 amps , only 10kw is used when w1 is energized 

300

A abnormally low suction pressure in the heat pump mode of operation could indicate _________

Dirty outdoor coil , restriction , fan motor not operating as should , etc. 

300

What is the difference between a Gam air handler and Tam air handler? What is the same thing they share 

They are both plastic cabinets but only the Tam units were designed to do communicating  

400

This component shuts the furnace off in the event of over-heating

High Temperature limit

400

When is the reversing valve energized

Depends of the manufacturer 

O typically energizes in cooling 

B typically energizes in heating 

400
Can a electric heater be re-strug
Yes
400
If a gas furnace starts, runs for a few seconds, shuts down, and repeats this process, the problem is most likely
Defective flame sensor/rectification
400

Trane’s patented air cleaner, designed to remove up to 99.98% of allergens.

Clean Effects 

500

How many heat exchangers does a 90 percent furance have

500

Because heat pumps circulate less refrigerant at low temperatures, this component stores excess refrigerant.

Suction Accumulator

500

When is an electric heater referenced as a emergency heater

When the heat pump has failed or in defrost mode 

500

60 psig    270 psig 

sh - 7        sc- 6 

vsat 23 

lsat 89 

outdoor temp 68 

low airflow 

500

What is the warranty on our Supreme 20 seer unit compressors  

12 year warranty