Electircal
Airflow
Refrigerant Issues
Why is it hot in here?
I want AHS to replace my system.
100

The system is not turning on at all and the thermostat is blank.

What is power loss/clogged drain

100

The condensor fan motor is humming and will run if you bump it

what is a bad capacitor

100

An R-22 system is running 43/125 psi with 80 deg OD temp and not cooling

What is low on refrigerant

100

A client with cars that have Alaskan plates is complaining that the thermostat will not maintain 62 degrees.  The home is 65 deg and it is 98 deg outside.

what is Sir you are crazy

100
No problems are found with the system.

what is have a nice day

250

Customer is complaining of $400 electric bills.

What is heat strips are running constantly

250

The refrigerant charge is good and the blower is running, but the coil is frozen.

What is a clogged filter

250

A 14 SEER system with a piston is pumping down in cool mode.

what is a clogged piston

250

A corner room in the southwest corner of the home is consistently 5 degrees warmer than the rest of the house.

what is more SA/RA

250

The customer states he's been paying for AHS for 16 years and they WILL replace his system.

what is you have $4350 of non-coverage

500
It is our 3rd trip, customer states the OD unit quits running in the middle of the day.  All coils are clean.

What is a bad condensor fan motor

500

A zone system blower motor continues to run for 5 minutes after the system satisfies.

what is a purge cycle

500

A one year old Evolution system is running in heat mode when it calling for cool.

what is a bad reversing valve solenoid

500

A new system in an 80 year old home has a brand new system that will not maintain the temperature.

what is poor insulation/ductwork/heat infiltration

500

An AHS customer with $10/# coverage has a bad compressor in a 14 year old system.

what is a $485 autho and a Comfort Advisor

1000

It is our 2nd trip.  OD breaker keeps tripping, but no problems have been found while we were there.

What is an intermittent HV short

1000

The system cools during the day, but at night the coil freezes. The system has a 26 deg temp split.

What is high static pressure

1000

A 15 year old system has high head pressure and a low suction, the piston is not clogged and all coils are clean.

what is a clogged filter dryer

1000
A system has a 5 degree temp split in cool mode. Pressures and airflow good.

what is heat strips are running in heat mode

1000

An AHS customer with full coverage is tired of continually repairing the system and wants to know how much money we can get from AHS.

what is call Rusty or David