Furnace
Refrigerant Cycle
Low Voltage Wiring
General #1
General #2
100

This part of a gas line helps to catch debris and moisture.

What is a drip leg.


100

This component creates a pressure drop in the system.

what is a metering device

100

R in the low voltage wiring represents this

What is 24v L1/Power


100

This prevents oxidation while brazing.

What is flowing Nitrogen.

100

This represents the equation to calculate subcooling.

What is SCT - LLT.

200

This will represent the units of measurement for gas pressure.

What are InWC

200

This component moves the refrigerant through the system.

What is the compressor

200

The G low voltage control string represents this

What is L1 control string for the Indoor Fan

200

SLT - SST is the equation used to calculate this 

What is Suction Superheat

200

The total percentage that you can add to a recovery tank's capacity.

What is 80%

300

A furnace comes from the factory set up for this type of fuel.

What is natural gas

300

This scientific law states heat migrates to cold.

What is 2nd law Of Thermodynamics

300

The Y low voltage control string represents this.


What is the L1 control string for the compressor and outdoor fan motor.

300

This is the correct way to wire a drain line safety switch.

What is in series with 24v L1/power 

300

This is the proper charging method when a system utilizes a TXV.

What is subcooling.

400

The nominal manifold outlet pressure on a gas valve utilizing natural gas.

What is 3.5 InWC

400

Superheat is the measurement of how much liquid is in this.

What is the evaporator.

400

The 24v wire L2 on a conventional split system runs from the furnace to what two components?

What are the thermostat and condenser.

400

This is the amount of heat required to raise 1 LB of water 1 degree.

What is 1 BTU

400

When checking airflow, the Anemometer will display what unit of measurements?

What is Feet Per Minute (FPM).

500

This type of pipe is used to flue an 80% gas furnace.

What is B-Vent

500

These are the four components of the refrigeration cycle

What are the compressor, condenser coil, metering device and evaporator coil


500

The O/B low voltage control string represents this.

What is the L1 control string for the reversing valve.

500

FPM x .75 x SqIn (return grille) / 144 represents what method for determining CFM?

What is the Traverse Method.

500

This is an acceptable micron level when pulling a system evacuation after 7 minutes of decay time.

What is 500-1000