Fired Up!
Pump It Up!
Safety Shutdown
Pipe Dreams
Tricks of the Trade
100

Adding glycol to a hydronic system does what?

Reduces heat transfer

100

Low water cutoffs are required on all boilers (True or False)

True

100

What can cause cavitation?

Air in the system

100

What control directly operates the zone valve motor?

Thermostat

100

What controls the temperature of the water in the boiler?

Aquastat 

200

How do you find the actual delta T on a boiler?

Supply minus return

200

What is the most commonly used type of expansion tank?

Diaphragm-type

200

Temperature and pressure of water have a ______________ proportional relationship

Dirrect

200

The low water cut-off shuts off what?

Burner and circulating pumps

200

The reason we use an expansion tank on hydronic heating systems is because?

Water does not compress

300

What is the purpose of fluxing a joint before soldering?

To clean the joint for capillary action

300

If the pressure in a residential hydronic system is at 28#, what should you look for?

Pressure reducing valve may be stuck open

300

What is the voltage used to operate a zone valve motor?

24V AC

300

The TH terminal on a zone valve goes to what?

Zone Valve Motor

300

The wiring from the gas valve should be connected to what 2 terminals inside the aqua-stat relay?

B1 and B2

400

When is an automatic float type air vent closed to the atmosphere?

When it is full of water

400

The boiler pump on a 90% plus unit should be mounted where?

So the inlet is near expansion tank connection

400

The recommended hole to drill out for finn tubed baseboard risers would be _____ Larger than the pipe size.

1/2 inch

400

What type of hydronic system uses water temperatures that normally do not exceed 120 degrees?

In floor Heat

400

What temperature difference (Delta T) are we looking for in residential boilers?

20 degrees

500

Where is it acceptable to use 50/50 non-lead free solder?

Non potable water lines

500

Where should you install the Make-up Air Valve on a boiler?

There is no such thing as a make-up air valve

500

Which of the following components would not be controlled by an aquastat controller?

zone valve

500

Why must we be careful not to overheat the pipe we are soldering?

Burn the Flux

500

The reason for a mixing valve (3 Way) on in-floor heat is to ___________

Reduce the water temp