PACS stands for
Picture Archiving and Communication System
Essentials of Radiographic Physics and Imaging - Pg 125
The glass envelope made of
Pyrex glass - Borosilicate glass
Essentials of Radiographic Physics and Imaging - Pg 55
Amorphous Silicon
Essentials of Radiographic Physics and Imaging - Pg 116
Material a transformer is comprised of
Soft Iron
Essentials of Radiographic Physics and Imaging - Pg 43
Automatic Exposure Control (AEC) can also be called
Phototiming
Essentials of Radiographic Physics and Imaging - Pg 172
High kVp, Long scale, ...
Low contrast
Essentials of Radiographic Physics and Imaging - Pg Pg 206
A dual focus tube refers to a tube with
2 filaments, large and small
Essentials of Radiographic Physics and Imaging - Pg 58
Job of Cesium Iodide
Convert x ray to light
Essentials of Radiographic Physics and Imaging - Pg 115
Rectification
Essentials of Radiographic Physics and Imaging - Pg 46
Minimal Response Time (MRT)
Essentials of Radiographic Physics and Imaging - Pg 175
How you would find pixel size
FOV/Matrix size
Essentials of Radiographic Physics and Imaging - Pg 102
The anode is the ___ end of the tube
Positive
Essentials of Radiographic Physics and Imaging - Pg 55
In Computed Radiography, the photo-stimulable phosphor is
Europium Doped Barium Fluorohalide
Essentials of Radiographic Physics and Imaging - Pg 114
High frequency rectification ripple
Less than 1%
Essentials of Radiographic Physics and Imaging - Pg 48
Most common radiographer error while using AEC
Selecting a detector
Essentials of Radiographic Physics and Imaging - Pg 172
Primary factor influencing contrast with digital systems
Look Up Table (LUT)
Essentials of Radiographic Physics and Imaging - Pg 122
The part(s) of the X-ray tube is located outside the glass envelope
Stators
Essentials of Radiographic Physics and Imaging - Pg 56
In Indirect Digital Radiography, this serves a similar purpose as a Charged Coupled Device (CCD)
Complementary Metal Oxide Semiconductor (CMOS)
Essentials of Radiographic Physics and Imaging - Pg 116
Job of generators
Converts mechanical energy into electrical energy
Essentials of Radiographic Physics and Imaging - Pg 41
When operating at or above 50 kVp, back up timers are terminated at a maximum of
600 mAs
Essentials of Radiographic Physics and Imaging - Pg 175
With a sufficient technique and low signal-to-noise ratio, this increases the contrast along the edge of a structure
Edge Enhancement
Essentials of Radiographic Physics and Imaging - Pg 120
Formula for calculating Heat Units
kVp x mA x s x c
Essentials of Radiographic Physics and Imaging - Pg 60
In Direct Radiography, x-rays are absorbed by
Amorphous Selenium, a-Se
Essentials of Radiographic Physics and Imaging - Pg 116
Materials of a rectifier
Solid State Diodes
Essentials of Radiographic Physics and Imaging - Pg 46
The increment, +3 , on the density controls is equal to (assuming common increments)
+75%
Essentials of Radiographic Physics and Imaging - Pg 176