BONE GRAFT & MEMBRANE
OVERDENTURE CONVERSION
IMPLANTS
RETRIEVALS
RESTORATIONS
100

How long does it take CREOS allo-protect membrane to resorb?

4-8 weeks

100

A mandibular overdenture requires a minimum of how many implants?

2

100
Primary stability during implant placement is achieved at what ncm?

35

100

If the abutment screw is fractured at the head, what can be use to remove it? 

Hemostat/pliers 

100

What restorative color is Yellow for Nobel implants?

Regular platform

200

Creating a hole in the center of the membrane to go over the healing abutment is known as the following technique

Poncho
200

When ordering locator abutments, where do you measure the tissue from?

Head of implant to height of tissue

200

Nobel active implants distinguishing feature is:

Self threading 
200
What tool is used to remove a locked in abutment, with a screw that is removed?

Abutment release pin

200

What ncm torque does a restorative implant screw need?

35 ncm

300

When repairing a boney defect, the membrane must extend how many mm beyond the defect?

2 mm

300

What part snaps down onto the locator abutment during conversion?

Black processing male

300

If an implant achieves less than 35 ncm but more than 15ncm, what is placed to seal the implant?

Cover screw

300
This tool is used when the implant screw channel can not be engaged.

Trephine drill 

300

What degrees do multi-unit abutments come in?

Straight (0), 17, 30

400
Xeno-gain graft requires how many months of healing before re-entry?

9-12 months

400

If this part is missed during overdenture conversion, the denture will lock in. 

White spacers

400

When placing a temporary abutment and crown on a single unit implant, you must ensure the crown's 100% out of 

Occlusion
400

The tool used to remove an implant that has a screw channel that can be engaged.

Implant removal tool 

400

For an AOX restoration, how many degrees can the posterior implants tilt?

45 degrees 

500

What procedure must be done to the buccal plate prior to ridge augmentation grafting?

Decortication 

500

The colored order of retention strength for locator housings is:

Blue - Pink - White

500

This tool can be used to remove excess bone that's grown around the head of the implant.

Bone mill 

500

The implant retrieval tool can be connected to both:

Manual torque wrench adaptor or motor hand-piece 

500

After the initial impressions are taken with impression copings for an AOX restoration, the next step in the treatment is:

A jig try in