FDA Says:
It's A Bugs Life
Who woulda thought?
Let's Get Rid of It
Because They Said So!
100

TRUE OR FALSE: Despite FDA recommendations, studies show that a repeat high level disinfection(AER) is not an effective way to reduce contamination.

What is: TRUE

100

TRUE OR FALSE?  There is an antibiotic treatment for all strands of bacteria:

What is: FALSE

100

TRUE OR FALSE? Recently, the FDA recommended healthcare providers transition to duodenoscopes with disposable components or fully disposable devices:

What is: TRUE

100

This is the most important step in endoscope reprocessing because it removes clinical soil and helps prevent biofilm formation:

A. pre-clean   B. Manual clean  C. High level disinfectant (AER)



What is: B. Manual Clean  

100

According to the Ofstead study showing the reprocessing steps of an endoscope.  What % of the reprocessed scopes were considered to have 0 mistakes:

A. 1.5%    B. 35.5%     C 65.5%    D.  95.5% 

What is: A. 1.5%

200

In 2018, FDA researchers inspected 24 bronchoscopes that had been cleaned and disinfected at three different medical centers. From this test they found that ___ bronchoscopes had irregularities apparent to the naked eye, including residues, retained fluid, scratches and other damage.  A. 16   B. 20   C. 24


What is: C. 24 bronchoscopes, 100%.

200

CRE is a bacteria that does not respond to a powerful class of antibiotics. The infection has a ___ percent mortality rate of:

A. 20%  B. 35%  C. 50%  D. 70%


What is: C. 50%

200

There is a documented case of a patient in Europe having CRE bacteria in his body that laid dormant for four years.  This CRE infection was later linked to a ____ and the patient later died. (It is a type of scope)

What is: a duodenoscope

200

TRUE OR FALSE:  It's ok if the manual cleaning isn't thorough because the High Level Disinfectant (AER) will clean any remaining bacteria.

What is: False.  If Manual cleaning is not done properly, the next steps of scope reprocessing can be compromised.

200

TRUE OR FALSE: The SGNA recommends putting simethicone in a flush bottle to be used on multiple patients throughout the day:

What is: FALSE. 

Enzymatic detergents cannot remove simethicone or silicone-based lubricants from endoscopes and could provide protection for bioburden

300

According to the FDA, _______ is considered the "gold standard for cleaning and sterilization."  BUT it actually damages the scopes, creates cracks where bacteria can lodge and necessitating more frequent replacements. A. Repeat HLD   B. EtO (Gas)

C. Liquid Chemical Sterilization  D. Steam Heat

What is: D. Steam Heat

300

The CRE bacteria family consists of ____ different species:   A. 88    B. 110  C. 128   

What is: C. 128

300

TRUE OR FALSE? The FDA approves of the ATP test, which is an indicator of clinical soil after a scope has been cleaned (this is also the test most used by facilities to test for bioburden):


What is: FALSE, the FDA does not recognize this test as a guarantee to verify a scope is 100% bacteria free.

300

Depending on the scope, the Michelle Alfa clinical observation study has shown the manual cleaning of an endoscope could take as high as   ___ minutes to reprocess if done correctly:

A. 5  B. 10  C. 15  D. 25

 

What is: D. 25 minutes  

300

Since 2013 there have been ____  FDA communications about duodenoscope reprocessing issues.  

 A. 3   B. 6  C. 9  D. 12

What is: D. 12  (that is the most for any device used in hospitals)

400

The FDA recommends that duodenoscopes are returned to the manufacturer for inspection, servicing, and maintenance of the device how many times each year? 

What Is:   once per year

400

The creation of Biofilm formation requires which of these things:

A. water  B. Bacteria   C. Surface  D. Nutrients

E. All of the Above

What is: E. All of the above

400

TRUE OR FALSE?  Prophylactic antibiotics are no longer a guarantee protection from superbugs. 

What is: TRUE  (WHO) World Health Organization states that Antibiotic resistance is #5 in top 10 threats to humans.

400

According to the Michelle Alfa Clinical Observation, the average time spent reprocessing an endoscope in the lab was ___minutes.

A. 6.5  B. 10  C. 15.5  D. 25

What is: A. 6.5 minutes

400

The SGNA, AAMI and AORN recommends the use of a freshly prepared ____ during the pre-cleaning of every endoscope

A. water  B. detergent  C. enzymatic detergent

D. bleach

What is: C. enzymatic/cleaning solution

500

Recent tests performed by scope manufacturers at the demand of the F.D.A. found that 1 in ___ duodenoscopes retained disease-causing microbes like E. coli even after proper cleaning:  

A. 20   B. 30  C. 40  D. 50

What is: A. 20 duodenoscopes…...or 5% of duodenoscopes

500

Microbial biofilms, which are often formed by antimicrobial-resistant organisms, are responsible for ___% of the infections treated in the developed world.

A. 15% B. 40%   C. 65%    D. 80%

What is: C. 65%

500

True or False: In the Rauwers study, after fully reprocessing the duodenoscopes, microbial growth was only found in the elevator.

What is: False.  There were multiple sights on the scopes that tested positive for microbial growth.

500

There are over ____steps involved in properly reprocessing an endoscope:

A. 80  B. 100  C. 120  D. 140

What is: D 140!!!!

500

According to SGNA, AAMI and AORN, a leak test should be done ____ the manual clean. 

A. before

B. during

C. after

What is: A. before