In typical pool operation, the percentage of OA ranges from this to this.
What is 25-50%
This is the energy recovery device that Innovent makes in their factory.
What is a sensible flat plate heat exchanger?
This is the standard Innovent controller brand.
What is Carel?
These are two ways (of many) to decrease the sound of a custom DX system.
Low Sound Condenser fans
Housed compressor sections
Compressor sound blankets
This is a fantastic way to engage customers and get them familiar with Innovent as a brand and a company.
What is a customer visit?
These are two reasons Innovent pools are a sweet spot
What are Better IAQ due to more OA, Lower Operating cost, Simpler to Control, Easier to install, Factory Support During design, Repeatable, Energy Calculation Ability, Experience implementing this design
This energy recovery device consists of aluminum plates interwoven with a polymer membrane
What is an enthalpic plate heat exchanger
This allows users to view their Innovent unit operation through the internet if they connect and ethernet cable to the unit.
What is WebUI?
These are two ways (of many) Innovent has flexibility in designing refrigeration systems.
Non-standard aspect ratios of coils and refrigeration components
Variable rows, circuiting, dimensions on evap and condensing coils
Condenser fan and compressor options
Control sequence adaptability
Sound control through fans, sound blankets, housed compressors...
This is Innovent's closure rate on Basis of Design Pools.
What is 90%
This is the first stage of dehumidification in an Innovent Pool Unit
What is Outside Air
This energy recovery system features two energy recovery devices and wraps around the second energy recovery device with the goal of providing room neutral air.
What is a LASER-2
This is where you can go to find the Innovent Controls IOM.
What is Repnet?
On average, this is how many Innovent jobs ship with refrigeration
What is 50%
This is Innovent's new design program that you have access to right now.
What is Specmate?
This is when the compressors run in an Innovent Pool unit.
What is the outside air damper at maximum and space humidity above setpoint.
This energy recovery device does sensible only energy recovery but has the advantage of being able to have air tunnels in different units and different locations.
What is a run around glycol loop?
This is the sensor we use to put flat plate heat exchangers in defrost mode.
What is an Exhaust Leaving Air Temperature Sensor
This is the lowest discharge air temp that Innovent can achieve off of a custom DX system.
What is 42.
If Steve Grandelis was going to pick three things that Innovent was good at, this is what he would say.
High amounts of outside air, custom refrigeration, and controls
These are two of the things that ASHRAE 62.1 doesn't take into account for pool ventilation
Space height
Air Distribution
Activity of the space
This energy recovery device features dampers that control the flow of air through a media
What is Accubloc?
These are two reasons why Controls are a sweet Spot for Innovent.
Experience in custom refrigeration control
Standard selectable, tested sequences
On staff controls engineers
Factory mounted controls
These are two reasons (of many) why you would use a custom DX system for your application.
non-standard fan, coil and compressor types required
Design efficiency strategy
Dimensional constrains for refrigeration system
Limited Space available/job constraints
limited location for outdoor air and exhaust louvers
Custom control sequence required
Aesthetically pleasing/curbside appeal
ability to locate in different locations/orientations
Sound
"plug and play" packaged unit is easier to install and less risk
Differentiation from competition
Large custom unit or high rise replacements
Full redundancy
This is the best way to get an Innovent job.
BOD