Mini Split A
Mini Split B
Split System A
Split System B
100

On mini-split systems both refrigerant lines must be insulated because they are both:

Low pressure and low temperature in the cooling mode.

100

Before beginning the installation, the first thing the installing technician should do is:

Read the installation instructions and make a list of materials.

100

 A typical residential split system air conditioner consists of an:

Outdoor condensing unit, an indoor evaporator, and an air handler.

100

Two common methods for measuring airflow in residential systems are:

Temperature rise or static pressure drop.

200

The refrigerant lines for single zone mini-split air conditioners are usually connected by:

Flare fittings.

200

The most reliable source for information regarding system installation is:

The manufacturer's installation manual.

200

A watertight, flexible electrical cable connecting the system's disconnect to the condensing unit

A Whip

200


How is the refrigerant charge normally checked on air-conditioning systems that use a fixed orifice expansion device?

superheat

300

Where are indoor units on mini splits typically mounted?

Wall Mount, Ceiling Mount

300

What is needed to use your gauges on a mini split system when charging?

5/16 in to 1/4" Adapter

300

Where is solid 18-gauge copper wire typically used in residential air-conditioning installation?

The thermostat control wire

300

What is the minimum SEER rating for new systems?

14 Seer

400

The indoor unit of a mini split is powered from where?

Outside unit.

400

VRF systems are commercial systems. The outdoor units are normally designed to operate on ________ phase power and the indoor units on ________ phase power.

Three and single

400

The condensate line from the drain pan of the evaporator is normally constructed of

3/4-inch  PVC.

400

What happens if a system is oversized for its application?

An oversized system will not run long enough to properly dehumidify the structure.

500

Variable refrigerant flow systems use what type of metering device?

EEV

500

A type system that allows simultaneous heating and cooling to different parts of a building is the:

Heat recovery system.

500

What is the standard airflow across the evaporator of a 3-ton residential split-system air conditioner?

1,200 CFM

500

How is the refrigerant charge normally checked on air-conditioning systems that use has a TXV? 

Subcooled