The Maximum distance above the ground you can be without proper fall protection
What is 6 feet
The name of the most important chapter
What is 690!!!
image 1
What is a 1 hole strap and a Mini (mineralic)
The "take up" of 1/2", 3/4" and 1" EMT 90
6" and 8"
What SED first did for work
What is installing MET towers? Data towers to collect site information aka meteorological evaluation towers
the typical accepted rise/run ratio for setting up a ladder
What is 4:1?
The maximum amount of bends in conduit in-between pull points.
What is 360 deg?
Image 2
the dimensions of a q-cell 350, and the width of a UFO to the nearest 1/8 inch
What is 40.5"x 68.5"
and 3/8"
The proper way to plan a vacation
What is, Make a bamboo submission under "hourly vacation" at LEAST two weeks in advance.
Minimum number of screw to install in our typical hitch clip
Whatever the manufacturer directions says. Read the directions. Also acceptable answer: One in every hole!
Type of cable and size typically used for an overhead service feed for a 200a service
What is 4/0 SEU
image 3
What is a threaded nipple and threaded coupling
On Q-cell modules, rail can land here. (portrait orientation) Answer must be within one inch of actual.
Hint: think typical layout rail placement from panel edge.
What is 250-450mm (9.8"-17.7")
The chain of command from installers, and Kerry's time zone
Installer, Crew lead, Brad, Kerry
Kerry is in mountain time, Two hours behind us, Therefore don't contact her prior to 9:00am our time unless its an emergency.
This is a device used to keep people out of something. There is also a label with the name of the person who placed it.
What is Lock Out Tag Out aka LOTO?
The maximum breaker you can typically backfeed on a 100a msp, 250a msp, and 200a msp.
Bonus: what size breaker can you back feed on a panel with a 200a MB and 225A rated bus?
What is 20a,30a,40a?
Bonus: 70a
image 4
what is an expansion joint and TA
The color code of a cat5 connector end. (left to right with tab away)
what is Striped orange, Orange, Striped green, Blue, Striped blue, Green, Striped brown, Brown.
(Tab away)
GreenSpark (SED) was founded in.
When was 2002
this is what OSHA stands for
Occupational Safety and Health Administration
You install 6 feet of electric baseboard in a clients house. (225 watts/foot) you hardwire this onto a dedicated single pull breaker. you will be running this heater for 3 hours at a time. What size breaker and wire should you use?
20 a breaker with #12 wire
6x225w=1350w
1350w/120=11.25a
11.25ax1.25=14.1 a (continuous duty adjustment)
This must be a 20a circuit because you cant load a circuit for more than 80% of what its rated for.
Image 5
What is a GC-50 and a Weave or star washer
The torque value of a UFO
what is 80 in-lbs
Greensparks core values (Name three) extra points for all five
Believe in people
Keep it Real
Find Joy
Be a Leader
Work together