UH-OH, YOU'RE IN TROUBLE
GIVE ME SPACE, MAN
I'M FIRED UP ABOUT THIS
NOT COMPLAINING, JUST VENTING
DO YOU NEED HOME DEPOT
100

Requires that parties be notified when their rights are to be affected 

What is Procedural Due Process 

100

You need to comply with this code if means for natural light and ventilation can be from artificial light or mechanical ventilation

What is the International Building Code

100

Size of the emergency escape and rescue openings where the basements contain one or more sleeping rooms

What is a sill height of not more than 44" inches measured from the finished floor to the bottom of the clear opening

100

It is a connection between two otherwise separate piping systems whereby there my be a flow (water) from one system to the other

What is Cross Connection

100

Receptacle outlets better be installed or distributed this way in every kitchen, family room, dining room, living room, bedroom or any other room or area of dwelling units

What is installed so that no point measured horizontally along the floor line is more than 6 feet

200

Even though lawsuits continue to be brought against building officials, code officials still need to be concerned with legal consequences of their actions

What is liability

200

The minimum clear floor area in an efficiency unit for 2 (two) occupants

What is 220 square feet

200

Information for fire-resistant construction, projections, openings and penetrations of exterior walls of dwellings and accessory buildings without automatic sprinkler systems can be found in IRC

What is Table R302.2(1)

200

This item needs the required approved combination temperature and pressure-relief valve and relief valve discharge pipe shall be properly installed and maintained

What is a water heater

200

You better get a fence or an enclosure if you have more of this in your private swimming pool, or if your spa and hot tub doesn't have an approved cover

What is more than 24 inches of water

300

Upon inspection of an occupied building, you determine there is imminent danger of serious physical harm. You order the building vacated immediately and then post condemnation signs at these locations 

What is every entrance to the building

300

Needs to be provided at all times for residential occupancies, other than one-two family dwellings, the common hall and stairways

What is not less than a 60-watt standard incandescent light bulb

300

A smoke alarm in a newly constructed dwelling must get its primary power from this:

What is commercial power

300

This item needs to be in legible lettering, be permanent factory-applied and affixed to appliances so you can see the manufacturer's name, model and serial number

What is Label Information for labeling of appliances in Section M1303

300

Look out for this condition if the foundation system isn't firmly supported by footings or not properly anchored, not plumb and free from open cracks and breaks

What is in an Unsafe Condition

400

The code official has reasonable cause to believe that there exists violations at the premises. If entry to inspect the premises is refused, the code official shall use this recourse

What is to pursue recourse as provided by the law to secure entry

400

Where injurious, toxic, irritating or noxious fumes, gases, dusts or mists are generated, the air shall be exhausted to the exterior and not be recirculated to any space

What is Process Ventilation

400

Handrails that have a circular cross-section must measure between this minimum and maximum diameter

What is an outside diameter of at least 1 1/ inches and not greater than 2 inches

400

You wouldn't want contamination from liquids, solids or gases introduced into this supply or you could get sick

What is Protection of Potable Water Supply in section P2902

400

Basement hatchways shall be maintained to prevent the entry of ___________, ____________ and ___________.

What are rain, surface drainage water and rodents

500

A property has an existing notice for interior violations. The current owners are putting the property up for sale. Before transfer of ownership can take place, the law requires that the current owner do one of these two options.

What is fix the problem so that it meets code or give the code official a signed, notarized statement from the buyer that states they will accept full responsibility.

500

A microwave and coffee pot are allowed in a rooming unit, or a dorm but this needs the written approval of a code official

What are cooking facilities

500

Smoke alarms in dwelling must be installed in these 4 general places

What is inside every bedroom, just outside every sleeping area, each story of dwelling including basement and habitable attics and horizontally from a bathroom

500

It's important that gas piping systems are provided with shutoff valves. You can't have shut off valves in _______ locations and furnace _________

What are concealed locations and furnace plenums (an air compartment/chamber to which one or more ducts are connected/air distribution system)

500

The accumulation of garbage in every dwelling unit can be disposed of in one of these approved items

What is an approved mechanical food waste grinder, an approved incinerator unit or an approved leakproof, covered outside garbage container