WHAT COLOR SHOULD A GROUNDED CONDUCTOR BE IDENTIFIED?
A: GREEN, B: YELLOW WITH A GREEN STRIPE, C: WHITE OR GRAY, D: ANY OF THE ABOVE
C: WHITE OR GRAY
WHY IS ELECTRICAL CONTINUITY REQUIRED FOR METALLIC CONDUIT?
A: TO REDUCE VOLTAGE DROP
B: TO LIMIT GALVANIC CORROSION
C: TO ESTABLISH AN EFFECTIVE GROUND FAULT PATH
D: TO REDUCE ELECTROLYSIS
C: TO ESTABLISH AN EFFECTIVE GROUND FAULT PATH
GFCI PROTECTION IS REQUIRED FOR ALL 125V 15/20A RECEPTACLES INSTALLED WITHIN 6 FEET OF A SINK IN __________.
A: LAUNDRY ROOMS
B: BATHROOOMS
C: GARAGES
D: ALL OF THE ABOVE
D: ALL OF THE ABOVE
WHAT DOES THE ABBREVIATION NEC STAND FOR?
NATIONAL ELECTRIC CODE
WHICH NEC CODE SECTION CONTAINS DEFINITIONS?
ARTICLE 100
THE MINIMUM LENGTH OF FREE CONDUCTOR TO BE LEFT AT EACH JUNCTION BOX SHALL BE ______.
A: 6 INCHES, B: 8 INCHES, C: 10 INCHES, D: 3 INCHES
A: 6 INCHES
METAL WATER PIPES INSTALLED IN OR ATTACHED TO A BUILDING OR STRUCTURE SHALL BE BONDED TO ______.
A: THE SERVICE EQUIPMENT ENCLOSURE
B: THE GROUNDED CONDUCTOR AT THE SERVICE
C: THE GROUNDING ELECTRODE CONDUCTOR
D: ANY OF THE ABOVE
D: ANY OF THE ABOVE
RESIDENTIAL RECEPTACLE SPACING REQUIRES A RECEPTACLE WITHIN ___ FEET OF EVERY DOOR.
6 FEET
WHAT DOES THE ABBREVIATION GFCI STAND FOR?
GROUND FAULT CIRCUIT INTERRUPTER
WHICH NEC CODE SECTION GOVERNS RECEPTACLE SPACING?
ARTICLE 210 (210.52)
CONDUCTORS MARKED WITH ______ ON THE INSULATION ARE NOT APPROVED FOR A WET LOCATION.
A: THW, B:THHW, C: THHN, D: THWN
C: THHN
A ONE FAMILY DWELLING UNIT WITH A DEMAND LOAD OF 200A IS SUPPLIED WITH A 120/240V SINGLE PHASE ELECTRICAL SYSTEM FROM THE LOCAL UTILITY. WHAT IS THE MINIMUM SIZE THW ALUMINUM CONDUCTORS REQUIRED AS SERVICE ENTRANCE CONDUCTORS?
A: 1/0, B: 2/0, C: 4/0, D: 3/0
C: 4/0
KITCHEN COUNTERTOP SPACES WIDER THAN _____ INCHES REQUIRE A RECEPTACLE.
12 INCHES
WHAT DOES THE ABBREVIATION GEC STAND FOR?
GROUNDING ELECTRODE CONDUCTOR
WHICH NEC CODE SECTION GOVERNS GROUNDING AND BONDING?
ARTICLE 250
WHICH OF THE FOLLOWING LISTED CIRCUIT BREAKERS IS NOT A STANDARD RATING? A: 75A, B: 90A, C: 110A, D: 225A
A: 75A
ON A SINGLE PHASE 200A SERVICE, THE TWO GROUND RODS MUST BE AT LEAST ___ FEET APART.
6 FEET
KITCHEN COUNTERTOP RECEPTACLES SHALL NOT BE LOCATED MORE THAN ____ INCHES ABOVE THE COUNTERTOP.
20 INCHES
WHAT DOES THE ABBREVIATION NEMA STAND FOR
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION
WHICH CODE SECTION GOVERNS AFCI PROTECTION?
ARTICLE 210 (210.12)
WHICH OF THE FOLLOWING SHALL NOT BE LOCATED OVER THE STEPS OF A STAIRWAY?
A: GENERAL RECEPTACLES
B: OVERCURRENT DEVICES
C: SWITCHES FOR LUMINAIRES
D: JUNCTION BOXES
B: OVERCURRENT DEVICES
ON A SINGLE PHASE 200A SERVICE, THE MINIMUM SIZE COPPER GROUNDING ELECTRODE CONDUCTOR SHALL BE _____.
6AWG
36 INCHES
WHAT DOES THE ABBREVIATION AHJ STAND FOR?
AUTHORITY HAVING JURISDICTION
WHICH CODE SECTION GOVERNS RECEPTACLE OUTLETS?
ARTICLE 406