Code
Drain
Heat
Plumbing
Random
100

The National Plumbing Code states that water must reach this temperature to be considered "Hot".

120 degrees

100

This is the maximum allowable feet between outside clean-outs in a residential sewer main line.

100 feet

100

The heat potential of a substance is called _____ heat.

Latent

100

A device or valve installed in the building drain or sewer pipe where a sewer is subject to backflow, and which prevents drainage or waste from backing up into a low level or fixtures. (IPC)

Backwater valve

100

The amount of Btus in 1 ton of cooling.

12,000

200

This is the temperature air must be to be considered "Standard Air" as defined by International Mechanical Code.

70 degrees

200

A tank or pit that receives sewage or liquid waste, located below the normal grade of the gravity system and that must be emptied by mechanical means.

Sump

200

This is the measure of Latent Heat.

British Thermal Unit

200

This is defined as "the unobstructed vertical distance through the free atmosphere between the outlet of the waste pipe and the flood level rim of the receptacle into which the waste pipe is discharging" (IPC)

Air Gap

200

This is the year Gibson's became a company.

1983

300

The maximum spacing between pipe supports for PVC in a horizontal application according to International Mechanical Code.

4 feet

300

The minimum slope per foot for drain pipe from 3-6 inches according to International Plumbing Code.

1/8 of an inch

300

A small flame that is utilized to ignite the gas at the main burner or burners.

Pilot

300

This is the minimum outlet diameter for a sink drain. (IPC)

1 1/2 inches

300

Pressure on the high pressure side of a mechanical refrigeration unit is called

discharge or head pressure

400

It's the clearance distance for single wall flue pipe from combustible material on a residential gas boiler.

9 inches

400

This is the minimum diameter of the outlet for a floor drain. (IPC)

2 inch diameter

400

The amount of cubic feet per thousand Btu/h needed when drawing combustion air from a room. 

50

400

Gas fired water heaters are prohibited in sleeping rooms, bathrooms or closet areas accessed through a sleeping room or bathroom. This type of gas water heater is the exception to that rule.

Direct vent water heater

400

The liquid that condenses from a gas (including flue gas) caused by a reduction in temperature or an increase in pressure. (IFGC)

Condensate

500

The maximum spacing allowed between supports for PEX piping in a horizontal application according to International Mechanical Code. 

32 inches

500

This chemical based connection method is prohibited when joining two different types of plastic pipe together for a drainage system. (IPC)

Solvent joint

500

The opening in a cap, spud or other device whereby the flow of gas is limited and through which the gas is discharged to the burner.

Orifice

500

This is the minimum distance (in inches) required between the front of a water closet and any wall, fixture or door. (IPC)

21 inches

500

When running a tracer wire for an underground line in Allen County, this size of solid copper wire is required.

10 gauge