Fuel
Oil
Air
QSAS
MISC
100

What are the three specific inputs to the MEC?

CDP, CIT, N2

2J-F108-2-1 pg 1210

100

When testing for fuel contamination in the oil system, a flashpoint test should be accomplished on an oil sample. The flash point of a sample should not be below what temperature?

204.4°C (400°F) 

1C-135-2-2-2 pg 1573

100

What is MAX motoring speed defined as?

Less than 1% increase in N2 rpm in 5 seconds

1C-135-2-4-1-1 pg 286

100

Station ___ and back need EP’s

900

i don’t feel like putting references in anymore

100

What is the limit for an acoustical panel trailing edge gap?

0.5 inches 

2J-F108-2-1 pg 1894

200

This must be retarded to prevent engine speed from exceeding either fan speed or core speed limits.

Engine throttles

2J-F108-2-1 pg 302

200

What is the PN for the oil tank drain plug O-ring?

PN J221P910

1C-135-2-2-2 pg 1576

200

True or False

When starting engines, if EGT exceeds 600 C° before 40% N2 is reached, abort start.

False

1C-135-2-4-1-1 pg 286

200

APU EMERGENCY STOP PROCEDURE

Momentarily press #1 & #2 EMER STOP switches on QSAS control panel

200

What must the DC Voltmeter on BATT/MAIN BAT read when applying external power?

28 plus or minus 2 VDC

1C-135-2-2-2 pg 813

300

This ignition setting is selected during takeoff, landing, and adverse weather conditions to protect against flameouts.

Continuous ignition

2J-F108-2-1 pg 1387

300

True or False?
7808 and 23699 oil can be mixed.

True

2J-F108-2-1 pg 1843

300

This hardware item is attaches fan blades to the disk and is closely monitored for stress and wear.

Fan blade dovetails

2J-F108-2-1 pg 549

300

What is the APU start task

1C-135-2-2-2 14.50

300

On the fuel pump/MEC aluminum gasket, the seal material must be ___ higher above the aluminum surface.

0.018 in (0,46 mm)

2J-F108-2-1 pg 1063

400

When inspecting to isolate a leak in the check valve of the fuel nozzles, what borescope ports are used?

S12, S13, S14, S15

2J-F108-2-1 pg 1189

400

WOODARD DOUBLE
Normal oil consumption is less than ___ quarts per hour. However, acceptable oil consumption can be up to ___ qph.

0.4, 0.8 

1C-135-2-4-1-1 pg 930

400

What component converts pressurized fuel into rotary shaft power, driving through the bleed valve stop mechanism to the gear reduction stage of the bleed valve and master ball screw actuator assembly?

Bleed Valve Fuel Gear Motor

2J-F108-2-1 pg 1544

400

APU gives you a bit code of: 

white black black white black black.
o••o••

What does this mean?

High oil temp indication, engine shutdown. • APU shuts down immediately. • APU will not start.

400

WOODARD DOUBLE

Flight crew reports a hung start with low EGT. VSV static rig is within limits. What maintenance is required?

Replace MEC

1C-135-2-4-1-1 pg 506

500

This system provides smoother acceleration, reduces EGT overshoot, and adjusts fuel flow to establish corrected fan speed during throttle movement.

Power Management Control

2J-F108-2-1 pg 1061

500

At what OAT can 7808 oil be used to service engines?

-40°F or below 

1C-135-2-4-1-1 pg 146

500

Specifically, how far open/closed does the starter control valve have to be before the starter light turns on or off?

Approximately 5°

1C-135(RC)(II)-1 pg 1-280

500

What two lubricating compounds can be used for ENGINE SYSTEMS O-Rings AND threaded tubing fittings?

LUBRICAT-ING OIL MIL-PRF-23699

PETROLA-TUM VV-P-236

1C-135-2-16-1 pg 96

500

What channel must the MEDC be on to get ENG instrument reading with external power removed?

Channel C

1C-135(RC)(II)-1 pg 1-276