PPE
Electric Safety
Company Policies
Vehicles/Equipment
General Safety
100

The required basic PPE on a jobsite

 What is Hard Hat, Safety Glasses, Safety Vest, Leather work boots?

100
The abbreviation for QEW stands for?

Qualified Electrical Worker

100

The source for accessing company reports

What is the Document Portal?

100

Employees must perform this inspection prior to using any company vehicle or heavy equipment each shift.

What is a Pre-Trip Inspection?

100

This minimum distance must be maintained when storing excavated spoils near a trench edge.

2ft

200

This PPE is required when working near energized electrical equipment to reduce arc-flash injuries.

What is FR/AR (Flame-Resistant/Arc-Rated clothing)?

200

OSHA defines this as the minimum distance a qualified worker must maintain from an energized source unless wearing appropriate PPE

What is the limited approach boundary?

200

This policy mandates that any employee can stop work immediately when a safety risk is identified, without fear of retaliation.

What is Stop-Work Authority?

200

This piece of equipment must be mounted and secured in all company vehicles

What is a Fire extinguisher?

200

This excavation protection method uses angled trench walls to prevent cave-ins.

What is sloping?

300

This PPE must be inspected before each use because even a pinhole can compromise its integrity.

What is Di-Electric rubber gloves?

300

This device automatically shuts off power when a ground fault is detected.

What is a GFCI?

300

This is the amount of persons an approved First-Aid kit must be able to supply

What is 25?

300

This annual test must be documented and labeled with a sticker on the vehicle.

What is the DOT annual inspection?

300

This is the minimum depth at which a ladder must be present in an excavation protection.

4ft

400

This is the ratio for conducting a field visual and inflation inspection

90% visual, 10% inflation

400

This phenomenon can release temperatures of 35,000°F and is caused by the rapid release of electrical energy due to a fault.

What is an Arc flash?

400

This is the procedure to follow when MIOSHA arrives. (The 3 step procedure)

Provide officer Pre Job brief, ensure all potential violations are corrected, call Safety Department

400

This is the minimum type of License required to drive company vehicles

What is a Chauffer's License?

400

This log must be presented to you by an authorized DTE employee when protection on equipment is present.

What is a CMR? (Crew Member Record)

500

This is the voltage rating for Class 2 Di-Electric gloves

What is 17,000 volts

500

Underground utilities can create this dangerous electrical condition when metallic objects or machinery unintentionally bridge energized and grounded surfaces.

What is step and touch potential?

500

This needs to be documented on the Pre Job Brief when working on live electric.

What is Voltage?

500

The EOZ is the abbreviation for?

Equipment Operating Zone
500

This compliance rule prohibits workers from entering an excavation when this percentage reading appears during atmospheric monitoring.

 What is oxygen deficiency (below 19.5%) or hazardous gas levels above permissible limits?