What does LED stand for?
light emitting diode
Who is our big boss?
Nixon Oyugi
what is the square root of 4x144 ?
2x12
Light Meters
In a vapor compression HVAC System, the expansion device is located between?
1. Condenser and Compressor
2. Compressor and Evaporator.
3. Condenser and Evaporator.
4. Compressor and Sub-cooler.
3. Condenser and Evaporator
What is the acronym TRM NYS stand for and what Version are we on as of 1/1/2024?
Technical Resource Manual Version 11
What year did Kawi got established?
2016
What's the easiest dish to cook?
Milk with Cereal
How do we usually measure Light quality?
1. CCT
2. CRI
3. LPW
4. Fc
2. CRI
What is the scientific definition (Units ration) of EER of a system?
Energy Efficiency Ratio = Cooling output (BTU/hr) Divided by Input Power ( Watts).
IEER = Integrated Energy Efficiency Rating
What 5 general departments are there in Kawi?
Hint: This was in our Annual Forum
Business Development
Human Resources & Admin
Engineering Services
Support Services
Finance
DOUBLE POINTS! What company recently gave a woman a car for an unintentional ad that went viral?
Stanley
How do you define efficacy in lighting?
Lumens/ Watts ... How many Lumens do you get out of the watts inputting to the light
How many tons of refrigeration does this unit have?
Manufacturer: Lennox
Model #: LGH150H4MM1Y
Serial #: 5619E12890
12.5 Tons
How many employees does Kawi has?
15
Why did the computer go to the doctor?
it had a virus.
You need 3 since every ballast can power up to 2 lamps.
In a chiller plant, the compressor-powered input reading is 500kW and the condenser of a chiller rejects heat at a rate of 2300 kW. What is the COP of this chiller? And what is the definition?
COP= Kw of refrigeration/ kW Electricity = 4.6
For every 1kW OF electricity you get in, you get 4.6 kW Cooling out.
Pressure Developed by a fan is directly proportional to
(Speed)2
What type of consultancy does Kawi do?
How Many bricks do the empire state building has?
10 Million
What is the wattage of the following lamp. 75PAR30S/HAL/SP10
75 Watts
DOUBLE POINTS! Assume it is 88 Degrees outside with RH of 60% and some outside air dampers are broken, such as that an additional 3,000 CFM is entering the building.
How many additional tons of cooling do we need to get this warm air back to 55 Degrees Fahrenheit " Supply Air" at 100% relative humidity?
18.9 Tons