_________ is a term referring to the influence of the design on functional characteristic. For example, in a reinforced hose it would be the type of
reinforcement, pattern of reinforcement, core to cover ratio, and etc

Construction

100

A change using a chemical equivalent...It would it be considered a change

True

False

False

100

Definition

__________

All the operations establishing, within specified
conditions, the relation between the values of the quantity indicated by a measuring device or measuring system, or the values represented by a
material measure or by a reference material, and the corresponding values of the quantity produced by standard

Calibration

100

An external lab needs to be accredited to ISO/IEC 17025?

True

False

True

100

When in the project...the Identification of Measurement Equipment  needs to happen?

At RP4

200

Definition:

________ ___________ Complex mixture of polymers, organic and inorganic fillers, plasticizers/oils,antiozonants, curatives, process aids, activators, coagents, etc. that is processed
into shapes. Mixture is vulcanized into permanent form using a variety of mechanisms (sulfur, peroxide, resin, etc)

Rubber Compound

200

Definition

__________

Facility allowing to perform controls, tests, and calibrations in the following area of activity but not limited to those ones: Chemistry, metallurgy, dimensional, physics, electricity, reliability

Laboratory

200

Definition

________ _____

parts used to verify the functioning or malfunctioning
of Poka-Yoke or integrated controls.

Challenge Parts

200

What are the inputs to define the control plan of the
characteristics to be measured?

Customer drawings,Specs,
FMEA. FVP, OAP.../Plan
client,Specifications,
AMDEC, FVP,OAP

200

Definition

_____ ____

Systematic reading error by a measuring instrument

Bias error

300

Definition:

______ _______

Process of making the rubber compound utilizing mill mixing or internal (Tangential, Intermesh, Tilt, and etc). Utilizes a combination of time, temperature, power, fill factor, chamber temperature, ram pressure, and order of addition. Can be done as a single stage or in multiple stages

Mixing Process

300

Definition:

_____

Determining one or several characteristics in conformity with a procedure

Test

300

Give at least 2 examples of environment conditions

- Temperature,
- Moisture level,

300

For any equipment... must be known with the label if the equipment is validated for use?

True

False

True

300

Definition:

__________

The ability of a measuring instrument to provide readings that are free of systematic errors

Accuracy

400

Complete the sentence

If no material approval exists, a material proposal, estimated timing,and _________ _____ are compiled and submitted to complete the RFQ

a) Chemist appointed

b) validation costs

c) similar costs

b) validation costs

400

Definition:

__________ _________

All the operations necessary to ensure that
an item of measuring equipment conforms to the requirements corresponding to its use

Metrological confirmatio

400

Who is the responsible of the sample collection?

a)The CMM technician

b) The Lab technician

c) The requester

c) The requester

400

Complete the sentence

The selection of the ITME is done during the Product Design / Process
Engineering by the _______ _____ and with the assistance of the laboratory or CMM and test departments

project team

400

Definition:

__________

Variation in measurements obtained with one measuring instrument when used several times by an appraiser while measuring the identical characteristic on the same part

Repeatability

500

Definition

Determination if material can be processed without excessive scrap or quality defects. Additional features can include formability, machine amps, “stickiness”, odor, and etc

Processability

500

Definition:

___________

 Confirmation by tangible evidence that the
specified requirements have been satisfied


Verification

500

Who enters the PR in case of a sub contracted test?


Laboratory and Test / CMM Manager

500

AKWEL target is to select ITME whose minimum IT measurable is more than or equal to 8 x Ig but nevertheless accepts a value of 4 x Ig.

Where Ig means?

Overall uncertainty (Incertitude globale)

500

Definition:

____________

Variation in the average of the measurements made by different appraisers using the same gage when measuring a characteristic on one part

Reproducibililty