Beam Restriction
Distortion
Imaging errors
Focal Spot Size
Waveform Rectification
m
100

What are 2 types of ancillary devices used to limit the beam?

Lead blockers 

Lead masking 

100

What factors affect shape distortion?

Tube angle 

IR angle 

Part Angle 

100

An insufficient amount of mAs will produce and image with what artifact?

Quantum noise/mottle Underexposed 

100

Decreasing focal spot size will do what to spatial resolution?

improve or increase spatial resolution 

100

A radiographic exposure is taken on a high frequency unit. In order to maintain exposure using a single-phase full wave unit would require what technique changes?

double the mAs 

100

A grid should be used if the body part measures more than:

10 cm

200

What are the 4 different types of beam restrictors?

1. Collimators

2. Cones and cylinders

3. Aperture diaphragm 

4. Ancillary device

200

Tube angle will produce what type of shape distortion?

Elongation 

200

What imaging error occurs when the imaging plate or flat panel detector is grossly over penetrated?

Saturation 

200

The measure of the amount of detail in a digital image defines:

Spatial resolution

200

What is the voltage ripple for a single-phase system?

100%

200

What grid error is produced when a focused grid not placed right side up?

Upside down 

300

What is the most common beam restricting device and what impact does it have on contrast and patient dose?

Collimators 

Reduces patient dose 

Increases contrast 

300

In order to reduce size distortion what should be done to SID?

Increase SID to minimize magnification. 

300

What is blurring at the periphery called and what is another name for it?

Penumbra 

aka geometric blur 

Geometric factors will reduce or increase penumbra/ geometric blur 

reduce= long SID, Short OID, small focal spot size 

300

What factor determines the filament size and essentially the focal spot size? 

mA 

300

How many diodes are used in a single-phase full wave rectified unit?

4 diodes 

300

What grid error is produced when the grid is not perpendicular to the central ray?

Off-Level 

400

What are the 3 main reasons for restricting the x-ray beam?

Decrease patient dose

Decrease occupational dose 

Increase image quality 


400

What combination of SID and OID will produce an image with the largest magnification?

Low/short SID and high/long OID 

400

What are the geometric factors that influence spatial resolution?

Focal Spot Size 

SID 

OID 

400

What technical factor controls the temperature of the cathode filament in the x-ray tube?

mA 

400

The current produced in a high- frequency generator is accomplished by high-speed switches called:

Inverter Circuits 

400

The ability of a grid to absorb scattered radiation after it exits the patient, is termed the:

Contrast improvement factor 

500

What relationship do collimation and contrast have? 

Direct 

Increase collimation= decreasing field size= reduces scatter= increases contrast

500

What are the patient factors that influence spatial resolution?

Patient size 

Patient movement 

500

Describe the difference between image contrast and subject contrast:

Image contrast is the differences in grey on the display 

and subject contrast is the differential absorption from the patient. 

500

What are the ideal combination of settings for SID, OID and Focal spot size that will produce an image with the greatest spatial resolution?

Long SID 

Short OID 

Small focal spot

500

3-phase units consist of waveforms separated by how many degrees?

120 degrees 

500

What grid error is produced when the grid is not placed directly under the central ray?

Off-Center