The Fire Service
Health and Safety
PPE
Communications
Fire Behavior
100

This group of people developed the first municipal water systems. 

Who are the Romans  

Page 27 

100

This is the NUMBER ONE cause of Firefighter Death in the line of duty 

What is over exertion, stress, medical 


Page 39 

100

This is when your SCBA should be checked by YOU. 

What is first thing - everyday, every time. 

And after use. 

100

The Acronym PSAP stands for what ? 

What is Public Safety Answering Point 

911 call center ; Direct to PD/FD, Central Office or Alarm Center ....COMTEC , SERESA 


Page 133

100

This term describes the rapid chemical process that produces heat and light. 

What is Fire 



page 159

200

This City established the first formal fire regulations in 1630 when it banned wood chimneys and thatched roofs. 

What is Boston 


Page 22

200

This agency , along with others, develops and enforces government regulation on workplace safety. 

What is OSHA 

Occupational Safety and Health Administration. 

MIOSHA = Michigan OSHA


Page 41

200

Your Low-Air alarm will sound at what percentage of remaining air supply ?

What is 33 % 

This gives you time to egress/exit. 

If you "Pay" to get in, you may well "Pay" to get back out - you need to leave when your Low-Air Alarm goes off. 

200

This communication device should be carried by every firefighter. 

What is a Portable Radio , or Prep 

Portable = Handheld

Mobile = Rig Radio 

Base Radio = Station Radio 

Page 146 

200

Fuel, Oxygen, Heat , and this , form the components of a fire tetrahedron. 

What is Chemical Chain Reaction. 

Fuel, Oxygen, and Heat interact in a manner that creates a self-sustaining Chain Reaction and keeps the combustion process going. Its what Happens; not necessarily a Piece of the recipe for fire. 

Page 151 

300

This type of "rule" governs construction materials and frequently requires built-in fire prevention and safety measures. 

What are Building Codes


Page 25

300

Not wearing this device from initial attack to finish of overhaul is the most dangerous voluntary activity in the fire service.  

What is SCBA 

Breathing by-products of combustion causes Cancer. Period. Even if you can "handle it" it is the dumbest thing you can do 

Page 45 

300

The US DOT requires this testing on SCBA Bottles on a periodic basis and limits the number of years a SCBA cylinder can be used. 

What is Hydrostatic Testing 

Alum, Steel, Carbon-fiber = 5 years 

Kevlar , Fiberglass = 3 years 

300

This system of coded messages should NOT be used, as it can cause great confusion, and NIMS also recommends it not be used.  

What are 10 Codes 

Use plain English - we all know it  


Page 149

300

This is formed when Plastic and Foam products - such as furniture and PVC pipe, used in all construction - Burns. 

What is Hydrogen Cyanide 

It is EXACTLY what it sounds like. Hydrogen Cyanide was used to KILL Prisoners in a Gas Chamber. 

FYI: Phosgene gas was used as a weapon in WWI  ( AKA mustard gas )

Page 163

400

This is a way of organizing an incident by breaking down the overall strategy into smaller tasks. 

What is Division of Labor 

Engines do Engine work, Ladders do Ladder work, Rescue Companies do Rescue work, etc. 

Page 20 

400

This person is personally responsible for your safety. 

Who is YOU 

work as a team, follow orders, THINK ! 

Cancer is not cool nor is a badge of honor 


Page 63

400

The "Device" is built into Firefighter Coats to assist with dragging them to safety. 

What is a DRD 

Drag Rescue Device

It doesn't work if its in the coat wrong, or not at all 


400

This describes an urgent message such as a call for help or evacuation and takes precedence over all other radio traffic 

Emergency Traffic 

A MAYDAY call is a form of Emergency Traffic. MAYDAY can be called before a problematic event occurs. 

Page 154 definitions 

400

This term describes the volume of space in which cooler air is drawn to the fire and the volume of space in which hotter gases and smoke are escaping from the fire. 

What is a Flow Path 

Good idea to hang around in a flow path ? Why ? 


Page 165 

500

This concept requires that each firefighter answers to only ONE supervisor, each supervisor answers to only ONE boss, and so on...

What is Unity of Command 

- Establishes a chain of command ; a direct rout of responsibility from Firefighter up to the Fire Chief. 

FF, Sgt, Lt, Capt, BC, Deputy/Assist Chief, Fire Chief 

Page 20

500

This is completed when there is a change in operational strategy or when a situation occurs that could endanger firefighters. 

What is a PAR 

Personnel Accountability Report ; the Company Officer should know where the crew members are ad what they are doing. 

Page 59 

500

This State Skills Test Station requires you to get 100%    ( but its NOT the only one with that requirement )

What is SCBA Inspection; Skill Station # 1 , which may be combined with Skill Station # 2 SCBA Donning 

FYI: Skill Station # 1 may not be the first skill you demonstrate on practical test day. 

500

The acronym IC stands for what ? 

What is Incident Commander.

The Boss



500

This Class of Fire involves combustible cooking oils and fats in kitchens. 

What is CLASS K 

List and Describe the other classes of Fire for 500 Bonus Points. 


Page 169