Residential Service Codes
Receptacle
Residential Service Install
Electrical Symbols
Random
100

Each service disconnect shall be simultaneously disconnect all ungrounded service conductors...

NEC 230.74

100

What is a receptacle outlet?

An outlet where one or more receptacles are installed

100

This is usually supplied by the utility company after the install is complete.

Meter

100

St

Timer Switch

100

Maximum distance between staples.

4 1/2 ft

200

Service disconnect shall not be installed where?

NEC 230.70(B) Bathrooms

200

If a wall is 24in long should you or should you not install a recpetacle?

You Should

200

These connect the grounding electrode the the ground rod.

Acorn Clamp

200

SK

Key-operated switches

200

What unit of measurement is used for the diameter of wire?

MIL

300

When Raceways are expose to weather should they shall be/shall not be listed for wet locations?

NEC 230.53 Shall Be

300

Name 3 place where GFCI receptacles can be installed in a dwelling unit according to NEC code.

Bathroom,Kitchen counter, Outdoors, Basements, sinks, crawl spaces, and etc.

300

Green Screw mounted in the panel board?

Bonding Screw

300

Describe a Floor outlet

A circle with a dot in the middle

300

What is the formal name for a "redhead" for MC Cable

Antishort bushing

400

The service switch shall be/shall not be permitted on the supply side.

NEC 230.94 Exception no.1

400

Name 3 standard Amp ratings of a receptacle in a dwelling unit.

15, 20, 30, 40, or 50

400

What SE cable are we using for are residential lab?

SE-U 2,2,4 Awg

400

Describe a Transformer symbol

A square box with a T in the middle

400

The Miniumum wire size installed in a dwelling unit?

14 Awg

500

Are Meter Sockets considered service equipment?

NEC 230.66(B) Shall Not

500

A cord connector that is supplied by a permanently connect cord shall/shall not be considered a receptacle outlet?

Shall be

500

This must be atleast 3 ft long on every service.

Drip Loop

500

Describe a clothes dryer outlet.

Circle with 3 lines in it and a D on the bottom right

500

If more the 20 current carrying conductors are in a bundle for longer than 24in what is the adjustment factor rating?

60%