Questions
Questions
Questions
Questions
Questions
100

In a universal motor, setting the brushes to the neutral plane can be done by connecting voltage to the armature, a voltmeter to the series field, and adjusting the brush position for a ___ on the voltmeter. 

Minimum 

100

When the field winding of a DC motor is connected in parallel with the armature, the motor is called?

Shunt 

100

The consequent pole motor is essentially a ____ speed motor. 

Two 

100

When reduced voltage is applied to the armature and full voltage is maintained to the shunt field, the motor operates at _________

Underspeed

100

The component of a DC generator that converts the armature AC into DC is the _______

Commutator

200

In a motor that has a rotating magnetic field, the speed of that magnetic field is refereed to as?

synchronous speed 

200

The output voltage of a shunt generator is set when the load is?

disconnected 

200

When voltage is applied to the both the armature and shunt field, the motor operates at? 

Base Speed 

200

the output voltage of a series generator is set when the load is ________

Connected

200

In a compound DC motor control circuit, the field loss relay will disconnect the ________ if power is lost to the ________.

Armature, Shunt Field

300

What type of motor must never operate under a no load condition?

series 

300

Armatures are wound to provide high voltage, high current or some specific combination of voltage and current. The winding that provides moderate voltage and current is the  ___ wound.

Frogleg 

300

In the shaded pole motor, the shading coil acts like a(n) ____ transformers secondary.

shorted 

300

The speed regulation of a DC motor is proportional to the __________

Resistance of the armature

300

A force that tends to cause rotation is known as  ______.

Torque

400

In a universal motor, inductive compensation can be used when the motor is connected to?

AC Only 

400

The compound connection that is rarely used is?

Differential 

400

In a two-phase power system has two voltages which are?

90 degrees out of phase 

400

The rotating part of a generator is called the ____

Armature

400

Armature reaction is the bending of the main magnetic field by the _________ magnetic field.

Armature

500

The Holtz motor is a variation on the shaded pole motor. It operates at ___ RPM.

1200 RPM

500

The magnetic field is sometimes provided by electromagnets. This is done by windings that are wound around what?

Pole Pieces 

500

A generator containing both series ans shunt field windings is called a ___ generator. 

compound 

500

The output voltage of a shunt generator is usually controlled by the amount of ________

Field excitation current

500

Conductive compensation is accomplished by connecting the compensating winding in ______ with the armature.

Series