The classification of Parking Garages.
Unclassified (511.3(A))
Code describing the scope of Aircraft Hangar requirements.
513.1
Code describing the Provisions for Maintenance and Service of Dispensing Equipment.
514.13
Code describing the Closed Construction of floating docks, piers, and wharfs and their classification information.
514.3(D)
Code describing Wiring and Equipment for Portable Lighting Equipment in Class 1 Locations.
511.4(B)(2)
(T/F) Lampholders of metal-shell,fiber lined types shall be used for fixed incandescent lighting.
False (513.7(D))
Code describing the Emergency Electrical Circuit Disconnects.
514.11(A)
Table describing the Electrical Equipment Classified Areas for Dispensing Devices.
514.3(B)(2)
Underground wiring below a Class 1 Location must be installed in these.
Threaded RMC or IMC (511.8)
Code describing Special Portable Lighting equipment requirements.
513.10(E)(1)
Class 1 Division 1(T514.3(B)(1))
Code describing the requirements for Wiring and Equipment above Class 1 Locations.
514.7
Classification (Class and Division) of Lighter-than-Air fuel major repair garages within 18in of the ceiling.
Class 2 Division 2 (511.3(D))
Classification (Class only) when above the floor, of Uninterrupted raceways that are embedded in a hangar floor.
Class 1(513.8(B))
(T/F) Grade level means the surface of a pier,extending down to water level for marine applications.
True (T513.3(B)(1)(Ex))
Classification (Class and Division) of the entire space within a protective enclosure for Vapor Processing Systems.
Class 2 Division 2 (T514.3(B)(1))
Classification of areas designed with positive air pressure, adjacent to the classified locations where flammable vapors are not likely to be released. (Lighter and Heavier-than-air locations)
Unclassified (T511.3)
Label text that must be permanently affixed to Mobile Stanchions with electrical equipment complying with 513.7(E).
WARNING
KEEP 5FT CLEAR OF AIRCRAFT ENGINES
AND FUEL TANK AREAS
(513.7(F))
Classification (Class and Division) of the entire space within any pit indoors located at remote pumps.
Class 1 Division 1 (514.3(B))
(T/F) PVC, RTRC, and HDPE conduits shall not be permitted where buried under more than 2ft of cover.
False (514.8(Ex2))