True or False: non-metallic boxes shall be acceptable only with metallic-sheathed cable and metallic raceways.
What is...True - 551.47 (c)
This code covers ground fault protection of floating buildings...
What is...555.63
NEC 590.3 States...
What is... REMOVAL- Temporary wiring shall be removed immediately upon completion of construction or purpose for which the hiring was installed.
Fixed Appliance
Article 590! First definition!...GO!
The working clearance for an RV Panelboard
What is...24 in. wide 30 in. deep - 551.45 (b)
The code cord-connected appliances for floating buildings is...
What is... 555.56 (b)
This code covers "protection from accidental damage"...
What is...590.4 (h)
Recreational Vehicle Site
The title of the chapter all of our assigned Jeopardy codes reside in...
The RV cord exposed usable length shall be measured from...
What is... The Point of entrance to the RV or face of flanged surface inlet (motor-base attachment plug) - 551.46 (b)
This code specifies the location of service equipment for docks and marinas... Where shall it be?
What is...It shall be on land adjacent to the structure - 555.4
This code covers over-current protective devices "where re-used"...
What is..590.8 (a)
Table 551.73 (a)...WTF is that??
What is...Demand factors for site feeders and service entrance conductors for park sites.
This article covers combination electrical systems, generator installations and 120v, 208v/120v, or 120v/240v nominal systems.
What is...551.4 (b)
This code covers transformers for marine hoists, railways, cranes, and monorails. Where shall it NOT be located??
What is...It shall NOT be located below the electrical plane. - 555.8
This code states that temporary power shall not exceed 90 days for holiday decorative lighting and similar purposes...
What is... 590.3 (b)
The first definition listed under article 590...
What is... there are no listed definitions in article 590.
This code covers "protection against physical damage" for underground services in an RV park...
What is... 551.80 (b)
This code specifies that the electrical connections shall be located at least 12 in. above the deck of a fixed pier, but shall NOT be located below the electrical datum plane.
What is... 555.30 (b)
This code covers "temporary receptacles in wet locations"...
What is...590.4 (d-2)
Dry Stack Storage
What is... A facility either covered or uncovered, constructed of horizontal and vertical structural members, designed to allow placement of small boats in defined spots arranged both horizontally and vertically.
The purpose of the NEC...
What is... Practical safeguarding of persons and property from hazards arising from the use of electricity.