APU
AC Electrical Systems
IDG
DC Battery and Inverter System
Ram Air Turbine
100

Sundstrand APS 2300

What is the make and model for the APU ?

100

Can power both AC buses on the ground.

What is the GPU?

100

IDG

What is the primary source of power? 

100

This Battery provides power to the APU's FADEC

What does Battery One ?

100

115VAC, 400Hz, 15 KVA 

What is the Voltage, Frequency, and Amperage rating for the RAT?

200

APU Temperature matches the airplane operational Envelope temperature. 

What is the Max start temperature for the APU?

200

Can provide power to both AC buses up to FL330? 

What is the APU?

200

This mode uses system logic to automatically controls the contactor. 

What is Auto Mode?

200

This battery provides power to the start buss for the APU.

What is Battery 2?

200

130 KTS

What is the minimum airspeed for the RAT?

300

30,000 feet

What is the max start altitude for the APU?

300

Permanently installed on the airplane for auxiliary power.

What is the APU?

300

This mode opens the Contractor manually?

What is the OFF position?

300

22.0 VDC

Min voltage during the Safety and Power on Checklist to consider APU start.

300

Can be activated manually or automatically deploys when when both AC Buses lose power to the ESS

What is the RAT?

400

-54 c

What is the minimum start temperature?

400

115 VAC, 400hz, 40KVA

What are the voltage, frequency and amp rating of the APU?

400

This mode mechanically disconnects the Constant Speed Drive from the IDG?

DISC

400

18.0 volts

What is the min voltage to close the battery contactor ?

400

VMO/MMO

What is the Maximum Airspeed for RAT operation?

500

33,000 feet

What is the max altitude for Electrical Generation?

500

Provides Emergency for power for critical components

What is the Ram Air Turbine? 

500

Crew cannot reconnect and is a maintenance function only. 

DISC mode 

500

-20 C. 

What is the Minimum Batt 2 temperature for starting ?
500

Slats and Flaps will operate at half-speed.

What will happen to the Slats and Flaps when the RAT is the main source of power?

600

15,000 feet

What is the max bleed altitude for the APU?

600

Onside, Inside, Outside, Cross-Side

What is the normal AC Electrical priority? 

600

115 VAC, 400HZ, 40KVA

What is the voltage, frequency and amp rating for the IDG?

600

provides 250v for engine starting. 

What is the voltage for the inverter?

600

This standby system will align itself in 90 seconds.

What is the Integrated Electronic Standby System?(IESS)

700

21,000 feet

What is the max Altitude for Assist for engine start?

700

Line Replaceable, Plug and play, there are four of them in various electronic bays.

What are the Integrated Control Center?

700

One Can power both AC buses on the ground or in flight. (2 installed on airplane)

What is the IDG ?

700

Has three of these, they rectify AC to 28 volts, 300A and are independent from each other

What are TRUs? Transformer rectifier units?

700

During an electrical Emergency this hydraulic accumulator will power flight controls until the RAT has powered the ACMP?

Accumulator 3

800

In flight this option is not available if exceeded

What is the auto shutdown if for excessive EGT?

800

Collect and confirm the power is safe

What are Secondary Power Distribution Assemblies.?

800

You see an amber light next to the IDG disconnect switch what does this indicate?

Indicates which IDG to disconnect.

800

provide 24 VDC at 27 AH

What is the voltage and amp hour rating for the  Batteries?

800

When the RAT is Deployed the DC ESS Busses 1 and 2 are supplied with current from these power sources.

What are Battery one and Battery two?

900

 717 degree Celsius.

What is the max temperature for Continuous Operation?

900

The Emergency lighting power units are powered by this electrical source.

What is DC Buss 1?

900

Disconnects AC Bus 1 from AC BUS 2

What are the AC Buss Tie Connectors? BTC

900

10 min

What is the Amount of time the batteries will last during an electrical emergency?

900

Battery Discharge light extinguishes.

How can you tell the RAT is Charging batteries and supplying voltage?
1000

1032C 

What is the Max EGT for start?