Health Effects
Engineering Controls
Article 32
Project Supervision
Containment
100

These individuals are more susceptible to mold exposure 

Who are young people, old people and people with allergies, asthma or compromised immune systems?

100

Most common engineering controls on mold projects

What are negative air ventilation and HEPA vacuums?

100

NYSDOL definition of a mold project

What is the cleaning, sanitizing or removal of more than 10 sf of mold?

100

Normally constitutes post remediation clearance 

What is a visual inspection by a certified assessor?

100

Warning signs are placed here

What is at the entry to containment?

200

Indoor Air Quality may be affected by these

What are air flow, contaminants, heat and moisture?

200

The arrangement of filters in ventilation equipment from the inlet side

What are pre-filter, intermediate filter and HEPA filter?

200

Prior to mold remediation, the property owner must first have this

What is a mold assessment?

200

A large mold project

What is greater than 100 sf?

200

Limited containment is generally recommended for these projects

What are projects 10 to 100 sf?

300

The most common symptoms of mold exposure

What are allergic reactions, flu-like symptoms, asthma, lung infections and neurological disorders?

300

Power tools used to disturb moldy materials must be equipped with this

What are a dust collection system with HEPA vacuum attachment?

300

Chemicals such as cleaners, biocides and antimicrobial sealants must have this

What is approval from the EPA for their intended use?

300

This ensures the project is completed in the event that the contractor fails to do so

What is a performance bond?

300

HVAC filters in mold impacted areas

What are disposed of as mold waste?

400

The danger from mold exposure varies depending on these three factors

What are dose, species and the individual?

400

HEPA filters are this efficient

What is 99.97% efficient to 0.3 microns?

400

This must be available on the jobsite for the duration of the remediation

What is the Remediation Work Plan?

400

This should be considered when deciding which cleaners and fungicides to use

What is occupant sensitivity?

400

Best work practices for cleaning up mold

Wet vacuums, desiccants, and de-humidifiers, wet wiping/scrubbing, HEPA vacuuming when dry

500

About 25% of the population carry this gene making them more susceptible to mold exposure.

What is the HLA-DR gene?

500

The number of ventilation units with 1500 CFM capacity necessary to move 75,000 cubic feet of air four times an hour

What is 3?

500

Specifies the level of PPE to be provided to remediation workers 

What is the Remediation Plan? or Who is the Assessor? 

500

Pre-bid considerations

What are clearance criteria, schedule, utilities, building occupants...? 

500

The three acceptable means of isolating the HVAC system

What are local isolation, shut down and isolation or positive pressurization?