TRUE/FALSE THE LENGTH OF THE CIRCUIT DETERMINES THE BRANCH CIRCUIT RATING.
FALSE IT IS RATED BY THE OVERCURRENT DEVICE
OUTDOOR RECEPTACLES ARE REQUIRED TO BE WHAT TYPE?
WEATHER-RESISTANT
IN SPIDER-MAN (2002) WHAT NEW YORK CITY NEWSPAPER EMPLOYS PETER PARKER?
THE DAILY BUGLE
ACCORDING TO 334.30 CABLE SHOULD BE SUPORTED AND SECURED AT INTERVALS OF WHAT?
4 1/2' 12" (8")
TRUE/FALSE GREEN, COPPER/GOLD, SILVER ARE THE 3 COLORS OF THE TERMINALS ON A STANDARD GROUNDING TYPE RECEPTACLE.
FALSE GREEN,GOLD/BRASS,SILVER
In NAPOLEON DYNAMITE (2004), WHAT ANIMAL DOES NAPOLEON TELL HIS CLASSMATES HE HUNTED IN ALASKA?
WOLVERINES
WHAT IS THE CROSS-SECTIONAL AREA OF THE CONDUCTOR IN CIRCULAR MILLS?
CMA
HOW MANY FEET OR LONGER DO HALLSWAY REQUIRE A RECPTACLE?
10
314.16
WHITE 14/2 BLUES 14/3 PURPLE 12/2 YELLOW 12/3
TRUE/FALSE WHEN WORKING WITH LOW VOLTAGE YOU CAN CONSIDER YOURSELF SAFE BECAUSE THE VOLTAGE IS THE MOST HARMFUL COMPONENT OF THE CIRCUIT.
FALSE
WHAT IS THE LARGEST SIZE SOLID WIRE PERMITTED IN A RACEWAY
10AWG
WHAT SIZE BREAKER WOULD YOU USE WITH 8 AWG ROMEX AND WHERE CAN YOU FIND THAT INFORMATION?
40 AMP TABLE 310.16
WHAT FILM MAKER MADE THE MOVIES HOUSE OF 1000 CORPSES AND THE DEVILS REJECTS?
ROB ZOMBIE
TRUE/FALSE AN IDCI MUST TRIP AT 3-5mA
FALSE 4-6mA
WHAT IS THE MINIMUM UNIT LOAD REQUIREMNT FOR DWELLING UNITS IS?
3 VA PER SQFT
WHAT ARE THE 3 SIZES OF SCREWS WE USE IN RESIDENTIAL AND WHERE WOULD WE USE EACH ONE?
6/32 DEVICES 8/32 LIGHTING 10/32 CEILING
WHAT CAUSES NUISANCE TRIPPING IN GFCIS?
LONG CIRCUIT RUNS
EXPLAIN HOW TO WIRE A 3 WAY STATING WHAT WIRE GOES ON WHAT TERMINAL.
HOT/LOAD GOES ON COMMON(BLACK) SCREW AND THE JUMPERS/TAVELERS GO ON THE BRASS. PIGTAIL THE GROUND AND CONNECT TO GREEN GROUNDING SCREW
WHAT IS THE NAME OF THE DEPARTMENT STORE BUDDY WORKS FOR IN THE MOVIE ELF?
GIMBELS
WHAT SIZE BOX WOULD YOU NEED YO HAVE AMPLE ROOM/VOLUME TO MEET CODE IF YOU HAVE
(1)3-WAY SWITCH
(1)DIMMER SWITCH
(1)SIGLE POLE
(2)14/3
(4)14/2
3 GANG 45 CU IN
IN THE MOVIE TAKEN(2008) WHERE IS BRYAN MILL'S DAUGHTER KIDNAPPED?
PARIS FRANCE
YOUR OVERALL SQUARE FOOTAGE IS 5400 INCLUDING
30'x20' LANAI
32'x12' ATTACHED GARAGE
WHAT IS THE MINIMUM NUMBER OF LIGHTING BRANCH CIRCUITS REQUIRED
8
WHAT IS THE VOLTAGE DROP AND WHAT IS THE MINIMUM WIRE SIZE TO INSTALL TO ACCOMPLSH THE 3% DROP.
240-VOLT BRANCH CUIRCUT THE SUPPLISES A RESISTIVE HEATING LOAD OF 15 AMPS. THE DISTANCE IS 100 FT.
7.2V 12AWG
WHAT IS THE MAX OPERATING TEMP FOR TW AND THHN IN CELCIUS AND WHAT TABLE IN THE NEC WILL YOU FIND THIS INFO IN?
60 DEGREES 90 DEGREES
TABLE 310.4(1) TABLE 310.16