Trophon
US Industry
Requirements
Nanosonics
NSM 2025
1000

The document for the trophon2 that involves setting up the device, running a disinfection cycle, and understanding its key features.

What is the quick reference guide?

1000

This company is a leader for POCUS and their ultrasound consoles are normally found in an ICU or Emergency Department

What is Fuji Sonosite?

1000

This list is normally provided by the HTM department prior to a site assessment.

What is an ultrasound asset list?

1000

7–11 Talavera Road, Macquarie Park, Sydney NSW 2113, Australia

What is Nanosonics Global Office?

1000

Built in 1886 in the Beaux-Arts architectural style with an eclectic flair and is known for its Carousel Piano Bar & Lounge

What is Hotel Monteleone?

1250

It is the international standard for storing, transmitting, and handling medical imaging information and related data

What is dicom?

1250

FDA, Medicare/Medicaid, Manufacturer's IFUs, Evidence-based Guidelines and National Standards, Consensus Documents, Organization's Infection Prevention and Control Policy.

What is The Joint Commission Hierarchical Approach Standards?

1250

10 inches of clearance around me, countertop, wall mount, or cart

What is the trophon placement requirement?

1250

This innovation provided a safer and more effective alternative to traditional disinfection methods, especially for both endocavity and surface probes. 

What is trophon EPR?

1250

NSM 2025 Opening Cocktail Reception Area

What is the Riverview room?

1500

A 2010 study that compares automated vs manual reprocessing methods

What is the Ofstead Study?

1500

This soaking chemistry requires a full PPE, can be used in a GUS Station, requires three 1 min. rinses, and a soaking time of 12mins at 68 degrees fahrenheit

What is Cidex OPA?


1500

If hazardous materials are present at a worksite in such a way that exposure could not occur then _____________ would not be necessary. This requirement is seen as a benefit to not being needed while using trophon (CIN048).

What is an eye-wash station?

1500

a cloud-based sales enablement platform designed to help organizations improve sales productivity, align go-to-market strategies, and drive revenue growth.

What is HighSpot?

1750

a healthcare IT professional responsible for managing the digital infrastructure that stores, retrieves, distributes, and displays medical images like X-rays, MRIs, CT scans, and ultrasounds

What is a PACS Administrator?

1750

For clinical applications of a semi-critical or critical nature(e.g., intraoperative, transrectal, transvaginal, transesophageal, or biopsy procedures), labeling should recommend, when appropriate, the use of sterile, legally marketed probe sheaths.  Note that the use of sheaths does not change the type of reprocessing that is recommended after each use 

What is the FDA Market Clearance of diagnostic ultrasound transducer and consoles document?

1750

This chemistry can be reused for up to 21 days provided it passes the MRC test strip and has a minimum 8 min soaking time.

What is Resert?

1750

required contract under the HIPAA Privacy Rule between a HIPAA-covered entity (like a healthcare provider or health plan) and a person or organization that performs services involving access to protected health information (PHI) on behalf of the covered entity.

What is a business associate agreement (BAA)?

1750

structured community of microorganisms—such as bacteria, fungi, or algae—that attach to a surface and produce a slimy, glue-like substance called extracellular polymeric substances (EPS)

What is Biofilm?

2000

A competitive product that has a minimum soaking time of 20 to 45 mins. and can be reused for up to 14 to 28 days.

What is glutaraldehyde?

2000

The document that states "No evidence the organization had a process in place to reprocess surface ultrasound transducers through high-level disinfection following a procedure involving direct exposure to non-intact skin and blood and/or body fluids as required by manufacturer's instructions 

What is The Joint Commission Newsletter from 2018?

2000

Minimum of 10 air exchanges per hour

What is a well-ventilated area?

2000

The studies that confirmed that Cidex OPA does not eradiate HPV (specifically 16 & 18). 

What are the Meyer's Studies or Penn State Studies?

2000

He is best known for his work in implementing and educating on systems like DICOM (Digital Imaging and Communications in Medicine), HL7, and IHE standards, which are foundational to medical imaging and health informatics

Who is Hermann Oosterwijk?