100

The minimum approved electrical trade size for EMT is ____ inches?

1/2

100

PVC bends must be made so that the conduit remains undamaged and the internal diameter of the conduit is ____?

not reduced

100

3/4" PVC must be supported/secured every ____?

3 ft

100

At least ____ inches of free conductor shall be left at each outlet, junction, and switch point?

6 inches

100

Cable installed under a building must be ____ unless the wiring method is type MC or MI cable that is identified for direct burial.

in a raceway

200

Honolulu is home to the world's largest _____?

A. Outdoor mall

B. Sugarcane farm

C. Beach

D. Ukulele

A. Outdoor mall (Ala Moana Center)




200

Cables entering or exiting conduit used for support or protection against physical damage require fittings on the conduit ends to prevent _____?

cable abrasion

200

What Atlanta company is one of the largest shipping couriers in the country?

A. Fed-Ex

B. Amazon

C. DHL

D. UPS

D. UPS

200

____ determines the minimum number of receptacles in a given dwelling?

wall space

200

What food retailer was founded in Austin?

A. Whole foods

B. Winn-Dixie

C. Piggly-Wiggly

D. Safeway


A. Whole foods

300

Contact of dissimilar metals should be avoided wherever possible to lessen the potential for ____?

galvanic action

300

What activity was invented in Tallahassee?

A. Knitting

B. Recycling

C. Streaking

D. Sun Bathing

C. Streaking

300

Electrical metallic tubing must not be _____?

threaded

300

What is the NHL team based in Nashville?

A. Opry Landers

B. Predators

C. Stingers

D. Stars

B. Predators

300

All cut ends of IMC and RMC must be _____?

reamed

400

Raceways installed within drop ceilings must _____?

have secure support provided by the support wires and associated fittings

400

Electrical installation openings that penetrate into or through fire-resistant-rated structures must be ____?

fire stopped

400

The equivalent of _____ is the maximum allowed between pull points?

four quarter bends (360 degrees total)

400

A general purpose branch circuit may feed_____?

lights, receptacles, or both

400

Cable running horizontally (or diagonally) are considered supported and secured when passing through a _____?

framing memeber

500
A key provision found in most of the cable articles states that the cable must not be installed where subject to _____?

Physical damage

500

Article 100 defines raceway as a/an _____ designed expressly for holding wires, cables, and busbars.

Enclosed channel of metallic (non-metallic) materials

500

The most common wiring type installed in one- family dwellings is _____?  

Nonmetallic-sheathed cable

500

Holes must be bored so that the edge of the hole is at least ____ from the nearest edge of the wood member.

1 1/4 inch

500

Nonmetallic-sheathing cable passing through holes (or slot) in metal framing must be protected by ____ covering all metal edges.

Listed bushings (or grommets)