The minimum approved electrical trade size for EMT is ____ inches?
1/2
PVC bends must be made so that the conduit remains undamaged and the internal diameter of the conduit is ____?
not reduced
3/4" PVC must be supported/secured every ____?
3 ft
At least ____ inches of free conductor shall be left at each outlet, junction, and switch point?
6 inches
Cable installed under a building must be ____ unless the wiring method is type MC or MI cable that is identified for direct burial.
in a raceway
Honolulu is home to the world's largest _____?
A. Outdoor mall
B. Sugarcane farm
C. Beach
D. Ukulele
A. Outdoor mall (Ala Moana Center)
Cables entering or exiting conduit used for support or protection against physical damage require fittings on the conduit ends to prevent _____?
cable abrasion
What Atlanta company is one of the largest shipping couriers in the country?
A. Fed-Ex
B. Amazon
C. DHL
D. UPS
D. UPS
____ determines the minimum number of receptacles in a given dwelling?
wall space
What food retailer was founded in Austin?
A. Whole foods
B. Winn-Dixie
C. Piggly-Wiggly
D. Safeway
A. Whole foods
Contact of dissimilar metals should be avoided wherever possible to lessen the potential for ____?
galvanic action
What activity was invented in Tallahassee?
A. Knitting
B. Recycling
C. Streaking
D. Sun Bathing
C. Streaking
Electrical metallic tubing must not be _____?
threaded
What is the NHL team based in Nashville?
A. Opry Landers
B. Predators
C. Stingers
D. Stars
B. Predators
All cut ends of IMC and RMC must be _____?
reamed
Raceways installed within drop ceilings must _____?
have secure support provided by the support wires and associated fittings
Electrical installation openings that penetrate into or through fire-resistant-rated structures must be ____?
fire stopped
The equivalent of _____ is the maximum allowed between pull points?
four quarter bends (360 degrees total)
A general purpose branch circuit may feed_____?
lights, receptacles, or both
Cable running horizontally (or diagonally) are considered supported and secured when passing through a _____?
framing memeber
Physical damage
Article 100 defines raceway as a/an _____ designed expressly for holding wires, cables, and busbars.
Enclosed channel of metallic (non-metallic) materials
The most common wiring type installed in one- family dwellings is _____?
Nonmetallic-sheathed cable
Holes must be bored so that the edge of the hole is at least ____ from the nearest edge of the wood member.
1 1/4 inch
Nonmetallic-sheathing cable passing through holes (or slot) in metal framing must be protected by ____ covering all metal edges.
Listed bushings (or grommets)