100

What does the acronym SCBA stand for?

Self Contained Breathing Apparatus.

100

A molecule of water contains how many hydrogen atoms?

2 (H2O)

100

What type of extinguisher is NOT to be used on a "C" class fire?

Class A (Air/Water extinguisher)

100

Heat, Fuel, Oxygen, and a Chemical chain reaction are the four components of what?

Fire Tetrahedron.

100

What is the duty of a Fire Boundary?

To prevent the fire from spreading to other spaces by heat transfer.

200

The fire fighting attack team uses the ______  to detect heat and/or fires on the other side of doors and bulkheads in the ship’s structure.

TIC

200

At what PSI does your SCBA begin to whistle?

1200 PSI

200

How long does it take to discharge a 15 pound (6.8kg) CO² extinguisher?

40-45 Seconds

200

What are the four (4) methods of extinguishing a fire?

Heat removal

Smothering 

Removal of fuel 

Flame interruption

200

What must a Sentry be wearing?

Must be wearing an SCBA and Bunker Gear.

300

"Left for life, Right to fight"

Refers to which piece of equipment?

Nozzle

300

How long does a 5 gallon (22 liters) of AFFF last at 6.9 bar (100 PSI)

Approximately 90 seconds

300

What two substances are used in a dry chemical extinguisher?

Potassium Bicarbonate & Nitrogen.

300

What must be worn to prevent the inhalation of toxic gas and smoke while fighting a fire?

SCBA

300

What is the best method for a “Fire Boundary” to tell if a bulkhead is cool?

By putting the back of their hand close to the bulkhead.

400

What allows you to attach two 1 1/2" lines to a hydrant or reduce a 2 1/2" line into two 1 1/2" lines

Wye Gate

400

What are the most common dimensions of fire hoses carried in HMC ships?

25/50 feet lengths

with 

1 1/2" and 2 1/2" diameters


400

What happens if I use a CO2 extinguisher on a Class A fire?

the flame would be extinguished but the deep seated embers would continue to burn.

400

The positions of an attack team?

ATTACK TEAM LEADER

NOZZLE

BACKUP

HYDRANT

400

Duties of a Sentry?

PPR

Preserve evidence.

Prevent Re-flash.

Restrict access.

500

How long does the EEBD last?

15 Minutes

500

What is the maximum length of fire fighting hose permitted between the nozzle and the eductor?

100 Feet

500

What type of fire is a Class D extinguisher used on?

Metal.

500

In what stage has the fire consumed the majority of the oxygen within a space and has reduced visually down to a small smoldering fire?

Decay.

500

When a boundary is set who must they inform immediately?

OOD/Section Base