system components
Monitor evaluate & adjust disinfection
Operate Equipment/maintenance
Laboratory analysis
Security, Safety & Administration
100

Head is measured in this unit

feet

100

the point at which the chlorine dosage has satisfied the chlorine demand

Breakpoint chlorination

100

a mechanical device consisting of 2 independently operating, spring loaded check valves with a reduced pressure zone between the 2 check valves

RPZ

100

a series of samples taken at different times from the sampling point and mixed together

Composite sample

100

A positive fecal coliform must be reported within

24 hours

200

water mains should primarily be sized primarily on this

fire flow and adequate pressures

200

booster chlorination should be added here

somewhere in the distribution system

200

a condition that can occur when pumps are run too fast or water is forced to change direction quickly

Cavitation

200

A collected sample that is accurately reflects the composition of water quality to be tested

Representative sample

200

The number of monthly distribution bacteria samples required is based on

population served

300

The measurement of a pipe's smoothness is known as this.

C-factor

300

The minimum required chlorine residual anywhere in the distribution system.

0.2 mg/L

300

a basic electrical unit that is used to measure a material's opposition to flow

Ohms

300

the water treatment process that kills disease-causing organisms in water, usually by the addition of chlorine

Disinfection

300

A system which fails to collect water samples in their distribution system would fall under which tier of public notification requirement

Tier 1

400

Protective methods for backflow-prevention devices in order of decreasing effectiveness are

Air gap, Reduced pressure zone, dual check valve assembly and vacuum breaker

400

Positive displacement meters typically do this when they are excessively worn

under-register

400

This type of valve can be used to to isolate a pump on the suction side.

Gate valve

400

This measurement for free chlorine residual is generally the simplest and quickest

DPD colorimetric method

400

the MCL for trihalomethanes

0.080 mg/L

500

This is the amount of liquid that can be raised vertically by a given pressure

Pressure head

500

This organism has the greatest resistance to chlorine

Giardia cysts

500

A rotating set of vanes that forces water through a pump

impeller

500

This chemical must be present to preserve a water sample when testing for total coliform

sodium thiosulfate

500

The surface water treatment rule requires disinfection residuals to be taken as the same time as these 

coliform samples