HVAC 1
HVAC 2
HVAC 3
HVAC 4
HVAC 5
100

RECEIVES THERMOSTAT INPUTS FROM MULTIPLE ZONES AND TELLS DAMPERS WHEN TO OPEN AND CLOSE AND THE HVAC EQUIPMENT WHEN TO RUN 

WHAT IS? 

ZONE BOARD 

100

A MESURMENT OF AIR FLOW. STATIC PRESURE IS A RESISTANCE THE FAN MUST OVERCOME TO PUSH AIR THROUGH THE DUCT SYSTEM 

WHAT IS?

CUBIC FEET MINUTE OR CFM 

100

HVAC metering devices that regulate refrigerant

fixed orifices (capillary tubes and pistons)

Modulating valves (TXV, EEVs, AXVs)


100

A MOTORIZED OR MANUEL FLAP INSIDE THE DUCTWORK THAT OPENS AND CLOSES TO CONTROL AIRFLOW TO A ZONE 

WHAT IS? 

ZONE DAMPER 

100

A THERMOSTAT CONTROLLING A SECONDARY ZONE IN A MULTI ZONE SYSTEM 

WHAT IS?

SLAVE T-STAT 

200

THE RESISTANCE TO RESISTANCE TO AIRFLOW IN THE DUCT SYSTEM, MEASURED IN INCHES OF WATER COLUMN (IN. W.C.)

WHAT IS?

STATIC PRESURE 

200

A DAMPER THAT REDIRECTS EXCESS AIR FROM THE SUPPLY DUCT BACK INTO THE RETURN DUCT HELP MANAGE STATIC PRESURE  

WHAT IS?

BYPASS DAMPER 

200

A SENSOR MOUNTED IN THE SUPPLY PLENUM TO MEASURE AIR TEMPUERATURE LEAVING THE HVAC UNIT 

WHAT IS?

DATS (DISCHARGE AIR TEMPERATUREB SENSOR) 

200

THE PRIMARY THERMOSTAT IN A ZONING SYSTEM TYPICALLY CONTROLS THE PRIORITY ZONE  

WHAT IS?

MASTER T-STAT (MASTER THERMOSTAT)

200

WHAT TYPE OF CAPACITORS ARE THERE IN AN HVAC SYSTEM 

WHAT IS?

RUN CAPACITORS AND START CAPACITORS

300

WHICH REFRIGERANT IS AN HCFC?

R-22        R-410     R134A     R-12


WHAT IS?

R-22

300

two ways to check compressor

Ohming and check to ground

300

TERM USED WHEN WEARING SAFTEY GLASSES, GLOVES, BOOTS,  

WHAT IS? 

PPE (PERSONAL PROTECTIVE EQUIPMENT)

300

PROCEDURE USED FOR DISCONNECTING AND LOCKING OUT POWER BEFORE SERVICING ELECTRICAL EQUIPMENT

WHAT IS?

(LOTO) LOCKOUT/TAGOUT  

300

WHAT DO YOU NEED WHEN YOU WORK IN AN AREA DEALING WITH REFRIGERANTS AND COMBUSTABLE GASES OR CHEMICALS 

WHAT IS? VENTILATION 

400

THIS SAFTEY DEVICE OFTEN TRIPS FIRST WHEN THERE'S AN ELECTRICAL SHORT ORVERLOAD 

WHAT IS A BREAKER OR FUSE 

400

IF YOUR SYSTEM HAS 120V ON THE PRIMARY BUT NO 24V ON THE SECONDARY, THIS PART HAS FAILED. 

WHAT IS THE TRANSFORMER?

400

THIS DEVICE ON THE WALL MUST CALL FOR COOLING OR HEATING BEFORE ANYTHING ELSE HAPPENS 

WHAT IS THE THERMOSTAT?

400

A DIRTY ONE OF THESE CAN CAUSE LOW AIRFLOW, HIGH HEAD PRESURE, OR A FROZEN COIL.

WHAT IS THE AIR FILTER?

400

THESE PASSAGES CARRY CONDITIONED AIR AND MAY BE COLLAPSED, BLOCKED, OR LEAKING.

WHAT ARE THE DUCTS?

500

A DIRTY ONE OF THESE OUTSIDE CAN CAUSE HIGH HEAD PREESURE AND POOR COOLING 

WHAT IS THE CONDENSER COIL?

500

WHEN SUCTION PRESURE IS LOW, IT COULD BE CAUSED BY UNDERCHARGE, RESTRICTION, OR THIS CONDITION. 

WHAT IS LOW airflow 

500

what does a vacuum pump do at least 2 answers

Removes air, moisture, and other contaminants

500

THE FURNACE MOTOR MUST START TO PROVE DRAFT BEFORE IGNITION 

WHAT IS THE INDUCER MOTOR?

500

A DIRTY ONE OF THESE CAN CAUSE BURNERS TO SHUT DOWNAFTER A FEW SECONDS 

WHAT IS THE FLAME SENSOR?