FURNACE BASICS
IGNITION & SAFTEY
AIRFLOW & COMFORT
TROUBLESHOOTING CODES
ADVANCED DIAGNOSTICS
100

THIS COMPONENT PROVES THAT THE FLAME IS PRESENT AND SAFE TO KEEP GAS FLOWING 

WHAT IS A FLAME SENSOR?

100

THIS DEVICE GLOWS HOT TO INGNITE THE GAS IN MANY MODERN FURNACES.

WHAT IS THE HOT SURFACE IGNITER? 

100

what powers the low voltage  

transformer

100

MOST FURNACES USE THESE FLASHING LIGHTS TO DISPLAY ERROR CODES. 

WHAT ARE LED ERROR CODE LIGHT'S?

100

THE FIRST STEP BEFORE TROUBLESHOOTING A FURNACE.

WHAT IS CHECK POWER SUPPLY AND THERMOSTAT CALL?

200

what is in-between  the low voltage terminal and transformer

low voltage fuse

200

IF THIS SAFTEY SWITCH OPENS DUE TO OVERHEATING, THE BURNER WILL SHUT DOWN. 

WHAT IS THE HIGH LIMIT SWITCH?

200

what prevents power to a unit for safety reasons

WHAT IS THE DOOR SWITCH?

200

WHAT TOOL IS USED TO INSURE PROPER COMBUSTION OF GAS IN A FLU PIPE 

WHAT IS A COMBUSTION ANALYZER?

200

A MANOMETER IS USED TO MEASURE THIS IN A FURNACE 

WHAT IS GAS PRESURE?

300

THIS DEVICE MONITORS VENT PRESURE TO ENSURE SAFE COMBUSTION AIRFLOW,

WHAT IS THE PRESURE SWITCH?

300

THIS HAPPENS IF THE FURNACE CONTROL BOARD DOES NOT SENSE A FLAME WITHIN A FEW SECONDS OF IGNITION 

WHAT IS A LOCKOUT OR IGNITION FAILURE?

300

HIGH TEMPERATURE LIMIT SWITCHES OFTEN TRIP BECAUSE OF THIS AIRFLOW-RELATED PROBLEM.

WHAT IS RESTRICTED AIRFLOW OR BLOCKED FILTER/DUCT?

300

A PRESURE SWITCH STUCK CLOSED BEFORE THE INDUCER STARTS CAUSES THIS FAULT?

WHAT IS AN INDUCER OR PRESURE SWITCH ERROR?

300

YOU WOULD USE A MULTIMETER SET TO THIS MODE TO CHECK FOR A BAD IGNITOR 

WHAT IS OHMS?

400

THE MAIN CONTROL CENTER OF A FURNACE, OFTEN WITH DIAGNOSYIC LED'S  

WHAT IS THE CONTROL BOARD?

400

THIS SAFTEY DEVICE TRIPS IF FLAMES ROLL OF THE BURNER AREA.

WHAT IS THE FLAME ROLLOUT SWITCH?

400

how many screws does a vent pipe require to secure it

3 for code

400

IF THE BLOWER RUNS CONTINOUSLY WITH NO HEAT, IT MAY BE DUE TO THIS TYPE OF LIMIT SWITCH FAULT.

WHAT IS AN OPEN HIGH LIMIT SWITCH?

400

WHEN TROUBLESHOOTING A TWO-STAGE FURNACE, THIS WIRE FROM THE THERMOSTAT TELLS THE CONTROL BOARD TO GO TO SECOND STAGE.

WHAT IS W2?

500

TWO-STAGE FURNACES TYPICALLY USE THIS TYPE OF THERMOSTAT SIGNAL TO COMMUNICATE STAGING.

WHAT IS W1 AND W2 THERMOSTAT TERMINALS?

500

how do you verify thermostat is bad

jump call for heat or cool

Y or W

500

what tool is needed to check gas pressure

WHAT IS a manometer

500

WHEN DIAGNOSING ERROR CODES, ALWAYS CHECK THIS DOCUMENT FIRST FROM THE FURNACE MANUFACTURER.

WHAT IS THE INSTALLATION OR SERVICE MANUEL?

500

what does Y mean on control board

cooling